Pro series common features
Sample to Answer
After designing an experiment through the Experiment Wizard, when a sample is injected, the kinetics evaluation value can be obtained through the automatic analysis function built into the iMSPR operating software.
Sustainable U-type fluidics module
Through the U-type fluidics module, the immobilization step can be shortened efficiently, and referencing can be performed perfectly without time lag. In addition, it can be used permanently since it is manufactured with a PEEK unibody.
Inlet 2
When using both channels (binding analysis)
Inlet 1
When immobilizing the ligand
Outlet
Automatic qualification check of sensor chip
The sensor chip status is checked before the experiment through the automatic check function built into the iMSPR operation software. You can secure more reliable data by checking initialization status.
In-line degassing system
If you use the iMSPR Pro series, degassing the buffer is unnecessary. The built-in degassing module reduces the failure rate of experiments by removing bubbles.
What are the differences between iMSPR Pro Series
.
Pro2X
ProX
Pro
Sample flow channel
4
two experiments per chip
4
one experiment per chip
2
one experiment per chip
Fluidics module
UFD Fluidics module with dual U-type flow cells
Standard Fluidics module with mono U-type flow cells
Standard Fluidics module with mono U-type flow cells
Sample injection
Autosampler with dual injection valve
48 vials rack x 2
96 well plate x 2
Autosampler with mono injection valve
48 vials rack x 2
96 well plate x 2
One by one
Sample volume (200ul sample loop)
Max 200ul Partial injection available 30 ~ 75 ul dead volume
Max 200ul Partial injection available 30 ~ 75 ul dead volume
Max 200ul Partial injection available 30 ~ 60 ul dead volume
Screening capacity
300 samples per day
150 samples per day
Not recommended
Add options, get powerful functions
Temperature control unit
In various temperature environments (10 to 40 degrees, room temperature dependent conditions), it is possible to obtain the value of the bonding properties and obtain the thermodynamic constants (enthalpy, entropy) through this. as well as biological temperatureThe binding properties of new drug candidates can be confirmed in the environment (37 degrees). Through this, predict the dynamics of the drug in the body and understand the bonding between molecules more completely.
Cooling unit
When a large amount of sample needs to be analyzed, drug candidates such as antibodies may be denatured due to the high temperature inside the autosampler. The cooling unit is a temperature cooling function inside the autosampler that can prevent this. It can cool down to 4 degrees, so you can safely analyze your samples until the end.
GxP Program
21 CFR compliance compliant programs can be installed.
Premium maintenance program