<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Immunology &#8211; Advena</title>
	<atom:link href="https://advena-bio.ae/aplications/immunology/feed/" rel="self" type="application/rss+xml" />
	<link>https://advena-bio.ae</link>
	<description></description>
	<lastBuildDate>Thu, 19 Sep 2024 10:28:03 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.8.1</generator>

<image>
	<url>https://advena-bio.ae/wp-content/uploads/2024/09/cropped-advena-favicon-32x32.webp</url>
	<title>Immunology &#8211; Advena</title>
	<link>https://advena-bio.ae</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Sony’s Reagents</title>
		<link>https://advena-bio.ae/shop/cell-biology/antibodies-for-flow-cytometry/sonys-reagents/</link>
		
		<dc:creator><![CDATA[Hattorihanzo]]></dc:creator>
		<pubDate>Thu, 19 Sep 2024 08:39:01 +0000</pubDate>
				<guid isPermaLink="false">https://advena-bio.ae/?post_type=product&#038;p=6511</guid>

					<description><![CDATA[To further life science research in the regenerative medicine and immunology fields, Sony has released a portfolio of dyes conjugated to antibodies, giving researchers new choices for panel design. The conjugates can be used in a variety of multicolor applications.]]></description>
										<content:encoded><![CDATA[<p>To further life science research in the regenerative medicine and immunology fields, Sony has released a portfolio of dyes conjugated to antibodies, giving researchers new choices for panel design. The conjugates can be used in a variety of multicolor applications.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>iMSPR-mini SPR system</title>
		<link>https://advena-bio.ae/shop/protein-analysis-biotechnology/spr/imspr-mini-spr-system/</link>
		
		<dc:creator><![CDATA[Hattorihanzo]]></dc:creator>
		<pubDate>Fri, 13 Sep 2024 08:40:25 +0000</pubDate>
				<guid isPermaLink="false">https://advena-bio.ae/?post_type=product&#038;p=6255</guid>

					<description><![CDATA[<p class="p1">Compact and easy to use SPR instrument for researchers, product developers, and medical sites.</p>]]></description>
										<content:encoded><![CDATA[		<div data-elementor-type="wp-post" data-elementor-id="6405" class="elementor elementor-6405" data-elementor-post-type="ae_global_templates">
				<div class="elementor-element elementor-element-3883099 e-flex e-con-boxed e-con e-parent" data-id="3883099" data-element_type="container">
					<div class="e-con-inner">
				<div class="elementor-element elementor-element-f702d0d elementor-widget elementor-widget-heading" data-id="f702d0d" data-element_type="widget" data-widget_type="heading.default">
				<div class="elementor-widget-container">
					<h3 class="elementor-heading-title elementor-size-default">Compact sized,
Incredible SPR system
iMSPR mini</h3>				</div>
				</div>
					</div>
				</div>
		<div class="elementor-element elementor-element-18e186a e-flex e-con-boxed e-con e-parent" data-id="18e186a" data-element_type="container">
					<div class="e-con-inner">
		<div class="elementor-element elementor-element-75c743a e-con-full e-flex e-con e-child" data-id="75c743a" data-element_type="container">
				<div class="elementor-element elementor-element-b3969db elementor-widget elementor-widget-heading" data-id="b3969db" data-element_type="widget" data-widget_type="heading.default">
				<div class="elementor-widget-container">
					<h4 class="elementor-heading-title elementor-size-default">mini is SPR itself</h4>				</div>
				</div>
				<div class="elementor-element elementor-element-238bcdc elementor-widget elementor-widget-text-editor" data-id="238bcdc" data-element_type="widget" data-widget_type="text-editor.default">
				<div class="elementor-widget-container">
									<p>mini is the basic model of iMSPR. Its optical platform is shared by all iMSPRs. All major parts are integrated into a small body.</p>								</div>
				</div>
				</div>
		<div class="elementor-element elementor-element-1758230 e-con-full e-flex e-con e-child" data-id="1758230" data-element_type="container">
				<div class="elementor-element elementor-element-a27f512 elementor-widget elementor-widget-image" data-id="a27f512" data-element_type="widget" data-widget_type="image.default">
				<div class="elementor-widget-container">
															<img fetchpriority="high" decoding="async" width="700" height="490" src="https://advena-bio.ae/wp-content/uploads/2024/09/0eb00b_f191f50a84b942a7807c9b53e684d801mv2.png.webp" class="attachment-large size-large wp-image-6272" alt="" srcset="https://advena-bio.ae/wp-content/uploads/2024/09/0eb00b_f191f50a84b942a7807c9b53e684d801mv2.png.webp 700w, https://advena-bio.ae/wp-content/uploads/2024/09/0eb00b_f191f50a84b942a7807c9b53e684d801mv2.png-300x210.webp 300w, https://advena-bio.ae/wp-content/uploads/2024/09/0eb00b_f191f50a84b942a7807c9b53e684d801mv2.png-600x420.webp 600w" sizes="(max-width: 700px) 100vw, 700px" />															</div>
				</div>
				</div>
					</div>
				</div>
		<div class="elementor-element elementor-element-1acdd26 e-flex e-con-boxed e-con e-parent" data-id="1acdd26" data-element_type="container">
					<div class="e-con-inner">
				<div class="elementor-element elementor-element-78e9cdd elementor-widget-divider--view-line elementor-widget elementor-widget-divider" data-id="78e9cdd" data-element_type="widget" data-widget_type="divider.default">
				<div class="elementor-widget-container">
							<div class="elementor-divider">
			<span class="elementor-divider-separator">
						</span>
		</div>
						</div>
				</div>
		<div class="elementor-element elementor-element-842479c e-con-full e-flex e-con e-child" data-id="842479c" data-element_type="container">
				<div class="elementor-element elementor-element-5657a95 elementor-widget elementor-widget-heading" data-id="5657a95" data-element_type="widget" data-widget_type="heading.default">
				<div class="elementor-widget-container">
					<h4 class="elementor-heading-title elementor-size-default">Sustainable I-type fluidics module

</h4>				</div>
				</div>
				<div class="elementor-element elementor-element-084ad5b elementor-widget elementor-widget-text-editor" data-id="084ad5b" data-element_type="widget" data-widget_type="text-editor.default">
				<div class="elementor-widget-container">
									<div id="comp-lk7yui972" class="HcOXKn c9GqVL QxJLC3 lq2cno comp-lk7yui972 wixui-rich-text" data-testid="richTextElement"><p class="font_7 wixui-rich-text__text">Two different samples can be injected simultaneously with the I-type fluidics module. A completely different sample can be injected, and one channel can be used as a reference. In addition, since the I-type fluidics module is manufactured with a PEEK-based unibody, it can be used semi-permanently.</p></div><div id="comp-lk7yui984" class="MazNVa comp-lk7yui984 wixui-image"><div class="j7pOnl" data-testid="linkElement"> </div></div>								</div>
				</div>
				</div>
		<div class="elementor-element elementor-element-cc773d2 e-con-full e-flex e-con e-child" data-id="cc773d2" data-element_type="container">
				<div class="elementor-element elementor-element-830e008 elementor-widget__width-initial elementor-absolute elementor-widget elementor-widget-icon-box" data-id="830e008" data-element_type="widget" data-settings="{&quot;_position&quot;:&quot;absolute&quot;}" data-widget_type="icon-box.default">
				<div class="elementor-widget-container">
							<div class="elementor-icon-box-wrapper">

			
						<div class="elementor-icon-box-content">

									<h3 class="elementor-icon-box-title">
						<span  >
							Inlet 						</span>
					</h3>
				
				
			</div>
			
		</div>
						</div>
				</div>
				<div class="elementor-element elementor-element-fe53b36 elementor-widget__width-initial elementor-absolute elementor-widget elementor-widget-icon-box" data-id="fe53b36" data-element_type="widget" data-settings="{&quot;_position&quot;:&quot;absolute&quot;}" data-widget_type="icon-box.default">
				<div class="elementor-widget-container">
							<div class="elementor-icon-box-wrapper">

			
						<div class="elementor-icon-box-content">

									<h3 class="elementor-icon-box-title">
						<span  >
							Outlet						</span>
					</h3>
				
				
			</div>
			
		</div>
						</div>
				</div>
				<div class="elementor-element elementor-element-ea12872 elementor-widget elementor-widget-image" data-id="ea12872" data-element_type="widget" data-widget_type="image.default">
				<div class="elementor-widget-container">
															<img decoding="async" width="596" height="346" src="https://advena-bio.ae/wp-content/uploads/2024/09/I-type.png.webp" class="attachment-large size-large wp-image-6271" alt="" srcset="https://advena-bio.ae/wp-content/uploads/2024/09/I-type.png.webp 596w, https://advena-bio.ae/wp-content/uploads/2024/09/I-type.png-300x174.webp 300w" sizes="(max-width: 596px) 100vw, 596px" />															</div>
				</div>
				</div>
					</div>
				</div>
		<div class="elementor-element elementor-element-0392c9f e-flex e-con-boxed e-con e-parent" data-id="0392c9f" data-element_type="container">
					<div class="e-con-inner">
				<div class="elementor-element elementor-element-37cd4e4 elementor-widget-divider--view-line elementor-widget elementor-widget-divider" data-id="37cd4e4" data-element_type="widget" data-widget_type="divider.default">
				<div class="elementor-widget-container">
							<div class="elementor-divider">
			<span class="elementor-divider-separator">
						</span>
		</div>
						</div>
				</div>
		<div class="elementor-element elementor-element-f957ef9 e-con-full e-flex e-con e-child" data-id="f957ef9" data-element_type="container">
				<div class="elementor-element elementor-element-6848774 elementor-widget elementor-widget-heading" data-id="6848774" data-element_type="widget" data-widget_type="heading.default">
				<div class="elementor-widget-container">
					<h4 class="elementor-heading-title elementor-size-default">Wherever you want
</h4>				</div>
				</div>
				<div class="elementor-element elementor-element-7eb00dd elementor-widget elementor-widget-text-editor" data-id="7eb00dd" data-element_type="widget" data-widget_type="text-editor.default">
				<div class="elementor-widget-container">
									<div id="comp-lk7yui972" class="HcOXKn c9GqVL QxJLC3 lq2cno comp-lk7yui972 wixui-rich-text" data-testid="richTextElement"><p class="font_7 wixui-rich-text__text">The mini can be powered only with a mobile PC and USB connection. Feel free to use mini anywhere.</p></div><div id="comp-lk7yui984" class="MazNVa comp-lk7yui984 wixui-image"><div class="j7pOnl" data-testid="linkElement"> </div></div>								</div>
				</div>
				</div>
		<div class="elementor-element elementor-element-229ae06 e-con-full e-flex e-con e-child" data-id="229ae06" data-element_type="container">
				<div class="elementor-element elementor-element-c66b793 elementor-widget elementor-widget-image" data-id="c66b793" data-element_type="widget" data-widget_type="image.default">
				<div class="elementor-widget-container">
															<img fetchpriority="high" decoding="async" width="700" height="490" src="https://advena-bio.ae/wp-content/uploads/2024/09/0eb00b_f191f50a84b942a7807c9b53e684d801mv2.png.webp" class="attachment-large size-large wp-image-6272" alt="" srcset="https://advena-bio.ae/wp-content/uploads/2024/09/0eb00b_f191f50a84b942a7807c9b53e684d801mv2.png.webp 700w, https://advena-bio.ae/wp-content/uploads/2024/09/0eb00b_f191f50a84b942a7807c9b53e684d801mv2.png-300x210.webp 300w, https://advena-bio.ae/wp-content/uploads/2024/09/0eb00b_f191f50a84b942a7807c9b53e684d801mv2.png-600x420.webp 600w" sizes="(max-width: 700px) 100vw, 700px" />															</div>
				</div>
				</div>
					</div>
				</div>
		<div class="elementor-element elementor-element-dc573f8 e-flex e-con-boxed e-con e-parent" data-id="dc573f8" data-element_type="container">
					<div class="e-con-inner">
				<div class="elementor-element elementor-element-031edc0 elementor-widget-divider--view-line elementor-widget elementor-widget-divider" data-id="031edc0" data-element_type="widget" data-widget_type="divider.default">
				<div class="elementor-widget-container">
							<div class="elementor-divider">
			<span class="elementor-divider-separator">
						</span>
		</div>
						</div>
				</div>
		<div class="elementor-element elementor-element-c4ac743 e-con-full e-flex e-con e-child" data-id="c4ac743" data-element_type="container">
				<div class="elementor-element elementor-element-b5ccc2e elementor-widget elementor-widget-heading" data-id="b5ccc2e" data-element_type="widget" data-widget_type="heading.default">
				<div class="elementor-widget-container">
					<h4 class="elementor-heading-title elementor-size-default">Whoever can access 
</h4>				</div>
				</div>
				<div class="elementor-element elementor-element-2d8234b elementor-widget elementor-widget-text-editor" data-id="2d8234b" data-element_type="widget" data-widget_type="text-editor.default">
				<div class="elementor-widget-container">
									<div id="comp-lk7yui972" class="HcOXKn c9GqVL QxJLC3 lq2cno comp-lk7yui972 wixui-rich-text" data-testid="richTextElement"><p class="font_7 wixui-rich-text__text">mini is easy. The magnetic base allows the fluidics module to be easily combined with the prism holder, and the preparation is completed by inserting the prism holder combined with the main body.</p></div><div id="comp-lk7yui984" class="MazNVa comp-lk7yui984 wixui-image"><div class="j7pOnl" data-testid="linkElement"> </div></div>								</div>
				</div>
				</div>
		<div class="elementor-element elementor-element-296b136 e-con-full e-flex e-con e-child" data-id="296b136" data-element_type="container">
				<div class="elementor-element elementor-element-baec3d7 elementor-widget elementor-widget-image" data-id="baec3d7" data-element_type="widget" data-widget_type="image.default">
				<div class="elementor-widget-container">
															<img decoding="async" width="800" height="499" src="https://advena-bio.ae/wp-content/uploads/2024/09/0eb00b_fcca5ff7346747539e406cc4a5a05898mv2-1-1024x639.gif" class="attachment-large size-large wp-image-6276" alt="" srcset="https://advena-bio.ae/wp-content/uploads/2024/09/0eb00b_fcca5ff7346747539e406cc4a5a05898mv2-1-1024x639.gif 1024w, https://advena-bio.ae/wp-content/uploads/2024/09/0eb00b_fcca5ff7346747539e406cc4a5a05898mv2-1-300x187.gif 300w, https://advena-bio.ae/wp-content/uploads/2024/09/0eb00b_fcca5ff7346747539e406cc4a5a05898mv2-1-768x479.gif 768w, https://advena-bio.ae/wp-content/uploads/2024/09/0eb00b_fcca5ff7346747539e406cc4a5a05898mv2-1-1536x959.gif 1536w, https://advena-bio.ae/wp-content/uploads/2024/09/0eb00b_fcca5ff7346747539e406cc4a5a05898mv2-1-2048x1278.gif 2048w, https://advena-bio.ae/wp-content/uploads/2024/09/0eb00b_fcca5ff7346747539e406cc4a5a05898mv2-1-600x375.gif 600w" sizes="(max-width: 800px) 100vw, 800px" />															</div>
				</div>
				</div>
					</div>
				</div>
		<div class="elementor-element elementor-element-e61320d e-flex e-con-boxed e-con e-parent" data-id="e61320d" data-element_type="container">
					<div class="e-con-inner">
				<div class="elementor-element elementor-element-c6562c2 elementor-widget elementor-widget-heading" data-id="c6562c2" data-element_type="widget" data-widget_type="heading.default">
				<div class="elementor-widget-container">
					<h3 class="elementor-heading-title elementor-size-default">Maximize through connection</h3>				</div>
				</div>
					</div>
				</div>
		<div class="elementor-element elementor-element-4e8bd7b e-flex e-con-boxed e-con e-parent" data-id="4e8bd7b" data-element_type="container">
					<div class="e-con-inner">
		<div class="elementor-element elementor-element-e7fc51f e-con-full e-flex e-con e-child" data-id="e7fc51f" data-element_type="container">
				<div class="elementor-element elementor-element-22f0111 elementor-widget elementor-widget-heading" data-id="22f0111" data-element_type="widget" data-widget_type="heading.default">
				<div class="elementor-widget-container">
					<h4 class="elementor-heading-title elementor-size-default">Extreme flexibility</h4>				</div>
				</div>
				<div class="elementor-element elementor-element-99802cb elementor-widget elementor-widget-text-editor" data-id="99802cb" data-element_type="widget" data-widget_type="text-editor.default">
				<div class="elementor-widget-container">
									<p>mini can connect with anything you can imagine. Challenge various applications by connecting to various devices based on 1/16 inch tubing.</p>								</div>
				</div>
				</div>
		<div class="elementor-element elementor-element-e22be4b e-con-full e-flex e-con e-child" data-id="e22be4b" data-element_type="container">
				</div>
					</div>
				</div>
		<div class="elementor-element elementor-element-31836dc e-flex e-con-boxed e-con e-parent" data-id="31836dc" data-element_type="container">
					<div class="e-con-inner">
				<div class="elementor-element elementor-element-c7c4418 elementor-widget-divider--view-line elementor-widget elementor-widget-divider" data-id="c7c4418" data-element_type="widget" data-widget_type="divider.default">
				<div class="elementor-widget-container">
							<div class="elementor-divider">
			<span class="elementor-divider-separator">
						</span>
		</div>
						</div>
				</div>
		<div class="elementor-element elementor-element-07b7c5e e-con-full e-flex e-con e-child" data-id="07b7c5e" data-element_type="container">
				<div class="elementor-element elementor-element-0e7c4d9 elementor-widget elementor-widget-heading" data-id="0e7c4d9" data-element_type="widget" data-widget_type="heading.default">
				<div class="elementor-widget-container">
					<h4 class="elementor-heading-title elementor-size-default">iMSPR-mini standard
</h4>				</div>
				</div>
				<div class="elementor-element elementor-element-10f3983 elementor-widget elementor-widget-text-editor" data-id="10f3983" data-element_type="widget" data-widget_type="text-editor.default">
				<div class="elementor-widget-container">
									<div id="comp-lk7yui972" class="HcOXKn c9GqVL QxJLC3 lq2cno comp-lk7yui972 wixui-rich-text" data-testid="richTextElement"><p class="font_7 wixui-rich-text__text">Standard mini models are supplied with an I-type fluidics module and tubing pump. It is possible to check the presence or absence of intermolecular bonds, to analyze approximate affinity and kinetics, and to conduct various application experiments.</p></div><div id="comp-lk7yui984" class="MazNVa comp-lk7yui984 wixui-image"><div class="j7pOnl" data-testid="linkElement"> </div></div>								</div>
				</div>
				</div>
		<div class="elementor-element elementor-element-ecbc2fe e-con-full e-flex e-con e-child" data-id="ecbc2fe" data-element_type="container">
				<div class="elementor-element elementor-element-6de51f2 elementor-widget elementor-widget-image" data-id="6de51f2" data-element_type="widget" data-widget_type="image.default">
				<div class="elementor-widget-container">
															<img loading="lazy" decoding="async" width="666" height="280" src="https://advena-bio.ae/wp-content/uploads/2024/09/미니-튜브-정면.png.webp" class="attachment-large size-large wp-image-6278" alt="" srcset="https://advena-bio.ae/wp-content/uploads/2024/09/미니-튜브-정면.png.webp 666w, https://advena-bio.ae/wp-content/uploads/2024/09/미니-튜브-정면.png-300x126.webp 300w, https://advena-bio.ae/wp-content/uploads/2024/09/미니-튜브-정면.png-600x252.webp 600w" sizes="(max-width: 666px) 100vw, 666px" />															</div>
				</div>
				</div>
					</div>
				</div>
		<div class="elementor-element elementor-element-f71d3e9 e-flex e-con-boxed e-con e-parent" data-id="f71d3e9" data-element_type="container">
					<div class="e-con-inner">
				<div class="elementor-element elementor-element-28d0028 elementor-widget-divider--view-line elementor-widget elementor-widget-divider" data-id="28d0028" data-element_type="widget" data-widget_type="divider.default">
				<div class="elementor-widget-container">
							<div class="elementor-divider">
			<span class="elementor-divider-separator">
						</span>
		</div>
						</div>
				</div>
		<div class="elementor-element elementor-element-6862bf6 e-con-full e-flex e-con e-child" data-id="6862bf6" data-element_type="container">
				<div class="elementor-element elementor-element-1a01f4b elementor-widget elementor-widget-heading" data-id="1a01f4b" data-element_type="widget" data-widget_type="heading.default">
				<div class="elementor-widget-container">
					<h4 class="elementor-heading-title elementor-size-default">For more accuracy
</h4>				</div>
				</div>
				<div class="elementor-element elementor-element-2f6332b elementor-widget elementor-widget-text-editor" data-id="2f6332b" data-element_type="widget" data-widget_type="text-editor.default">
				<div class="elementor-widget-container">
									<div id="comp-lk7yui972" class="HcOXKn c9GqVL QxJLC3 lq2cno comp-lk7yui972 wixui-rich-text" data-testid="richTextElement"><p class="font_7 wixui-rich-text__text">For more accurate kinetics evaluation, the experiment should be operated more stably. Try adding a degasser, injection valve, etc. for that purpose.</p></div><div id="comp-lk7yui984" class="MazNVa comp-lk7yui984 wixui-image"><div class="j7pOnl" data-testid="linkElement"> </div></div>								</div>
				</div>
				</div>
		<div class="elementor-element elementor-element-58aafed e-con-full e-flex e-con e-child" data-id="58aafed" data-element_type="container">
				<div class="elementor-element elementor-element-27466ea elementor-widget elementor-widget-image" data-id="27466ea" data-element_type="widget" data-widget_type="image.default">
				<div class="elementor-widget-container">
															<img loading="lazy" decoding="async" width="656" height="292" src="https://advena-bio.ae/wp-content/uploads/2024/09/KakaoTalk_20200413_090722592_edited.jpg.webp" class="attachment-large size-large wp-image-6277" alt="" srcset="https://advena-bio.ae/wp-content/uploads/2024/09/KakaoTalk_20200413_090722592_edited.jpg.webp 656w, https://advena-bio.ae/wp-content/uploads/2024/09/KakaoTalk_20200413_090722592_edited.jpg-300x134.webp 300w, https://advena-bio.ae/wp-content/uploads/2024/09/KakaoTalk_20200413_090722592_edited.jpg-600x267.webp 600w" sizes="(max-width: 656px) 100vw, 656px" />															</div>
				</div>
				</div>
					</div>
				</div>
		<div class="elementor-element elementor-element-669b9c3 e-flex e-con-boxed e-con e-parent" data-id="669b9c3" data-element_type="container">
					<div class="e-con-inner">
				<div class="elementor-element elementor-element-0bd42a6 elementor-widget-divider--view-line elementor-widget elementor-widget-divider" data-id="0bd42a6" data-element_type="widget" data-widget_type="divider.default">
				<div class="elementor-widget-container">
							<div class="elementor-divider">
			<span class="elementor-divider-separator">
						</span>
		</div>
						</div>
				</div>
		<div class="elementor-element elementor-element-22edde9 e-con-full e-flex e-con e-child" data-id="22edde9" data-element_type="container">
				<div class="elementor-element elementor-element-52f70cf elementor-widget elementor-widget-heading" data-id="52f70cf" data-element_type="widget" data-widget_type="heading.default">
				<div class="elementor-widget-container">
					<h4 class="elementor-heading-title elementor-size-default">For high throughput
</h4>				</div>
				</div>
				<div class="elementor-element elementor-element-df27255 elementor-widget elementor-widget-text-editor" data-id="df27255" data-element_type="widget" data-widget_type="text-editor.default">
				<div class="elementor-widget-container">
									<div id="comp-lk7yui972" class="HcOXKn c9GqVL QxJLC3 lq2cno comp-lk7yui972 wixui-rich-text" data-testid="richTextElement"><p class="font_7 wixui-rich-text__text">You may need to process a larger number of samples than you originally intended. Don&#8217;t buy a new device. By adding an autosampler to the mini, even a large number of samples can be processed.</p></div><div id="comp-lk7yui984" class="MazNVa comp-lk7yui984 wixui-image"><div class="j7pOnl" data-testid="linkElement"> </div></div>								</div>
				</div>
				</div>
		<div class="elementor-element elementor-element-7cddf5e e-con-full e-flex e-con e-child" data-id="7cddf5e" data-element_type="container">
				<div class="elementor-element elementor-element-4d8b3dd elementor-widget elementor-widget-image" data-id="4d8b3dd" data-element_type="widget" data-widget_type="image.default">
				<div class="elementor-widget-container">
															<img loading="lazy" decoding="async" width="478" height="444" src="https://advena-bio.ae/wp-content/uploads/2024/09/mini-활용_90.png.webp" class="attachment-large size-large wp-image-6280" alt="" srcset="https://advena-bio.ae/wp-content/uploads/2024/09/mini-활용_90.png.webp 478w, https://advena-bio.ae/wp-content/uploads/2024/09/mini-활용_90.png-300x279.webp 300w" sizes="(max-width: 478px) 100vw, 478px" />															</div>
				</div>
				</div>
					</div>
				</div>
		<div class="elementor-element elementor-element-317d300 e-flex e-con-boxed e-con e-parent" data-id="317d300" data-element_type="container">
					<div class="e-con-inner">
				<div class="elementor-element elementor-element-8892178 elementor-widget-divider--view-line elementor-widget elementor-widget-divider" data-id="8892178" data-element_type="widget" data-widget_type="divider.default">
				<div class="elementor-widget-container">
							<div class="elementor-divider">
			<span class="elementor-divider-separator">
						</span>
		</div>
						</div>
				</div>
		<div class="elementor-element elementor-element-8298ba7 e-con-full e-flex e-con e-child" data-id="8298ba7" data-element_type="container">
				<div class="elementor-element elementor-element-9cfab92 elementor-widget elementor-widget-heading" data-id="9cfab92" data-element_type="widget" data-widget_type="heading.default">
				<div class="elementor-widget-container">
					<h4 class="elementor-heading-title elementor-size-default">iMSPR-Lab</h4>				</div>
				</div>
				<div class="elementor-element elementor-element-643318f elementor-widget elementor-widget-text-editor" data-id="643318f" data-element_type="widget" data-widget_type="text-editor.default">
				<div class="elementor-widget-container">
									<div id="comp-lk7yui972" class="HcOXKn c9GqVL QxJLC3 lq2cno comp-lk7yui972 wixui-rich-text" data-testid="richTextElement"><p class="font_7 wixui-rich-text__text">The iMSPR-mini can be equipped with a variable angle module to study various films, various samples, various solvents&#8230;even gas sensors. Due to the variable angle module, the incident angle range is very wide from 40 degrees to 80 degrees. A wide angle of incidence range means no restrictions for your application.</p></div><div id="comp-lk7yui984" class="MazNVa comp-lk7yui984 wixui-image"><div class="j7pOnl" data-testid="linkElement"> </div></div>								</div>
				</div>
				</div>
		<div class="elementor-element elementor-element-914952d e-con-full e-flex e-con e-child" data-id="914952d" data-element_type="container">
				<div class="elementor-element elementor-element-bd032e9 elementor-widget elementor-widget-image" data-id="bd032e9" data-element_type="widget" data-widget_type="image.default">
				<div class="elementor-widget-container">
															<img loading="lazy" decoding="async" width="528" height="596" src="https://advena-bio.ae/wp-content/uploads/2024/09/0eb00b_1a5d6fcb3ed943dd804d7f20f5cd6f37mv2.png.webp" class="attachment-large size-large wp-image-6281" alt="" srcset="https://advena-bio.ae/wp-content/uploads/2024/09/0eb00b_1a5d6fcb3ed943dd804d7f20f5cd6f37mv2.png.webp 528w, https://advena-bio.ae/wp-content/uploads/2024/09/0eb00b_1a5d6fcb3ed943dd804d7f20f5cd6f37mv2.png-266x300.webp 266w" sizes="(max-width: 528px) 100vw, 528px" />															</div>
				</div>
				</div>
					</div>
				</div>
		<div class="elementor-element elementor-element-c283700 e-flex e-con-boxed e-con e-parent" data-id="c283700" data-element_type="container">
					<div class="e-con-inner">
				<div class="elementor-element elementor-element-8974dc6 elementor-widget elementor-widget-heading" data-id="8974dc6" data-element_type="widget" data-widget_type="heading.default">
				<div class="elementor-widget-container">
					<h3 class="elementor-heading-title elementor-size-default">Whatever,
wherever you want</h3>				</div>
				</div>
					</div>
				</div>
		<div class="elementor-element elementor-element-6c97702 e-flex e-con-boxed e-con e-parent" data-id="6c97702" data-element_type="container">
					<div class="e-con-inner">
		<div class="elementor-element elementor-element-b90f6e4 e-con-full e-flex e-con e-child" data-id="b90f6e4" data-element_type="container">
				<div class="elementor-element elementor-element-5b9ff91 elementor-widget elementor-widget-heading" data-id="5b9ff91" data-element_type="widget" data-widget_type="heading.default">
				<div class="elementor-widget-container">
					<h4 class="elementor-heading-title elementor-size-default">Diagnostic platform device</h4>				</div>
				</div>
				<div class="elementor-element elementor-element-2e7c759 elementor-widget elementor-widget-text-editor" data-id="2e7c759" data-element_type="widget" data-widget_type="text-editor.default">
				<div class="elementor-widget-container">
									<p>Develop a fluidics module according to your purpose. A mini can be a great sensor. mini will be a very suitable platform for diagnosing biomarkers in complex samples such as whole blood.</p>								</div>
				</div>
				</div>
		<div class="elementor-element elementor-element-e435f92 e-con-full e-flex e-con e-child" data-id="e435f92" data-element_type="container">
				<div class="elementor-element elementor-element-1ea963a elementor-widget elementor-widget-image" data-id="1ea963a" data-element_type="widget" data-widget_type="image.default">
				<div class="elementor-widget-container">
															<img loading="lazy" decoding="async" width="548" height="366" src="https://advena-bio.ae/wp-content/uploads/2024/09/0eb00b_304fbb36337e415d94ee0441c942810amv2.jpg.webp" class="attachment-large size-large wp-image-6288" alt="" srcset="https://advena-bio.ae/wp-content/uploads/2024/09/0eb00b_304fbb36337e415d94ee0441c942810amv2.jpg.webp 548w, https://advena-bio.ae/wp-content/uploads/2024/09/0eb00b_304fbb36337e415d94ee0441c942810amv2.jpg-300x200.webp 300w, https://advena-bio.ae/wp-content/uploads/2024/09/0eb00b_304fbb36337e415d94ee0441c942810amv2.jpg-360x240.webp 360w, https://advena-bio.ae/wp-content/uploads/2024/09/0eb00b_304fbb36337e415d94ee0441c942810amv2.jpg-68x45.webp 68w" sizes="(max-width: 548px) 100vw, 548px" />															</div>
				</div>
				</div>
					</div>
				</div>
		<div class="elementor-element elementor-element-2d282f9 e-flex e-con-boxed e-con e-parent" data-id="2d282f9" data-element_type="container">
					<div class="e-con-inner">
				<div class="elementor-element elementor-element-1cba299 elementor-widget-divider--view-line elementor-widget elementor-widget-divider" data-id="1cba299" data-element_type="widget" data-widget_type="divider.default">
				<div class="elementor-widget-container">
							<div class="elementor-divider">
			<span class="elementor-divider-separator">
						</span>
		</div>
						</div>
				</div>
		<div class="elementor-element elementor-element-6cad3ab e-con-full e-flex e-con e-child" data-id="6cad3ab" data-element_type="container">
				<div class="elementor-element elementor-element-0ccd34f elementor-widget elementor-widget-heading" data-id="0ccd34f" data-element_type="widget" data-widget_type="heading.default">
				<div class="elementor-widget-container">
					<h4 class="elementor-heading-title elementor-size-default">At physiological environment
</h4>				</div>
				</div>
				<div class="elementor-element elementor-element-d539ff6 elementor-widget elementor-widget-text-editor" data-id="d539ff6" data-element_type="widget" data-widget_type="text-editor.default">
				<div class="elementor-widget-container">
									<div id="comp-lk7yui972" class="HcOXKn c9GqVL QxJLC3 lq2cno comp-lk7yui972 wixui-rich-text" data-testid="richTextElement"><p class="font_7 wixui-rich-text__text">Confirmation of binding properties at biological temperature can be of great importance. The mini fits in your own dryer and can be used up to 50 degrees Celsius.</p></div><div id="comp-lk7yui984" class="MazNVa comp-lk7yui984 wixui-image"><div class="j7pOnl" data-testid="linkElement"> </div></div>								</div>
				</div>
				</div>
		<div class="elementor-element elementor-element-6978916 e-con-full e-flex e-con e-child" data-id="6978916" data-element_type="container">
				<div class="elementor-element elementor-element-0cf7d96 elementor-widget elementor-widget-image" data-id="0cf7d96" data-element_type="widget" data-widget_type="image.default">
				<div class="elementor-widget-container">
															<img loading="lazy" decoding="async" width="546" height="366" src="https://advena-bio.ae/wp-content/uploads/2024/09/0eb00b_fc340910f5a64632a07d2b24c223b19bmv2.jpg.webp" class="attachment-large size-large wp-image-6287" alt="" srcset="https://advena-bio.ae/wp-content/uploads/2024/09/0eb00b_fc340910f5a64632a07d2b24c223b19bmv2.jpg.webp 546w, https://advena-bio.ae/wp-content/uploads/2024/09/0eb00b_fc340910f5a64632a07d2b24c223b19bmv2.jpg-300x201.webp 300w, https://advena-bio.ae/wp-content/uploads/2024/09/0eb00b_fc340910f5a64632a07d2b24c223b19bmv2.jpg-360x240.webp 360w, https://advena-bio.ae/wp-content/uploads/2024/09/0eb00b_fc340910f5a64632a07d2b24c223b19bmv2.jpg-68x45.webp 68w" sizes="(max-width: 546px) 100vw, 546px" />															</div>
				</div>
				</div>
					</div>
				</div>
		<div class="elementor-element elementor-element-9034e64 e-flex e-con-boxed e-con e-parent" data-id="9034e64" data-element_type="container">
					<div class="e-con-inner">
				<div class="elementor-element elementor-element-9d47556 elementor-widget-divider--view-line elementor-widget elementor-widget-divider" data-id="9d47556" data-element_type="widget" data-widget_type="divider.default">
				<div class="elementor-widget-container">
							<div class="elementor-divider">
			<span class="elementor-divider-separator">
						</span>
		</div>
						</div>
				</div>
		<div class="elementor-element elementor-element-09a1b20 e-con-full e-flex e-con e-child" data-id="09a1b20" data-element_type="container">
				<div class="elementor-element elementor-element-fbd450d elementor-widget elementor-widget-heading" data-id="fbd450d" data-element_type="widget" data-widget_type="heading.default">
				<div class="elementor-widget-container">
					<h4 class="elementor-heading-title elementor-size-default">In cooling chamber
</h4>				</div>
				</div>
				<div class="elementor-element elementor-element-54a25f4 elementor-widget elementor-widget-text-editor" data-id="54a25f4" data-element_type="widget" data-widget_type="text-editor.default">
				<div class="elementor-widget-container">
									<div id="comp-lk7yui972" class="HcOXKn c9GqVL QxJLC3 lq2cno comp-lk7yui972 wixui-rich-text" data-testid="richTextElement"><p class="font_7 wixui-rich-text__text">Of course, the mini can do its part even in the cooling chamber.</p></div><div id="comp-lk7yui984" class="MazNVa comp-lk7yui984 wixui-image"><div class="j7pOnl" data-testid="linkElement"> </div></div>								</div>
				</div>
				</div>
		<div class="elementor-element elementor-element-5474a5f e-con-full e-flex e-con e-child" data-id="5474a5f" data-element_type="container">
				<div class="elementor-element elementor-element-2eda665 elementor-widget elementor-widget-image" data-id="2eda665" data-element_type="widget" data-widget_type="image.default">
				<div class="elementor-widget-container">
															<img loading="lazy" decoding="async" width="548" height="366" src="https://advena-bio.ae/wp-content/uploads/2024/09/0eb00b_50e5d63bea224a35987add21964ff042mv2.jpg.webp" class="attachment-large size-large wp-image-6286" alt="" srcset="https://advena-bio.ae/wp-content/uploads/2024/09/0eb00b_50e5d63bea224a35987add21964ff042mv2.jpg.webp 548w, https://advena-bio.ae/wp-content/uploads/2024/09/0eb00b_50e5d63bea224a35987add21964ff042mv2.jpg-300x200.webp 300w, https://advena-bio.ae/wp-content/uploads/2024/09/0eb00b_50e5d63bea224a35987add21964ff042mv2.jpg-360x240.webp 360w, https://advena-bio.ae/wp-content/uploads/2024/09/0eb00b_50e5d63bea224a35987add21964ff042mv2.jpg-68x45.webp 68w" sizes="(max-width: 548px) 100vw, 548px" />															</div>
				</div>
				</div>
					</div>
				</div>
		<div class="elementor-element elementor-element-95872b5 e-flex e-con-boxed e-con e-parent" data-id="95872b5" data-element_type="container">
					<div class="e-con-inner">
				<div class="elementor-element elementor-element-b049626 elementor-widget-divider--view-line elementor-widget elementor-widget-divider" data-id="b049626" data-element_type="widget" data-widget_type="divider.default">
				<div class="elementor-widget-container">
							<div class="elementor-divider">
			<span class="elementor-divider-separator">
						</span>
		</div>
						</div>
				</div>
		<div class="elementor-element elementor-element-e0c2938 e-con-full e-flex e-con e-child" data-id="e0c2938" data-element_type="container">
				<div class="elementor-element elementor-element-946c818 elementor-widget elementor-widget-heading" data-id="946c818" data-element_type="widget" data-widget_type="heading.default">
				<div class="elementor-widget-container">
					<h4 class="elementor-heading-title elementor-size-default">On-site education
</h4>				</div>
				</div>
				<div class="elementor-element elementor-element-5cbff45 elementor-widget elementor-widget-text-editor" data-id="5cbff45" data-element_type="widget" data-widget_type="text-editor.default">
				<div class="elementor-widget-container">
									<p>For student education, mini is a very suitable device. You can better understand the SPR phenomenon by directly adjusting the polarizer, and feel free to try the SPR device yourself.</p>								</div>
				</div>
				</div>
		<div class="elementor-element elementor-element-aaab42c e-con-full e-flex e-con e-child" data-id="aaab42c" data-element_type="container">
				<div class="elementor-element elementor-element-229647a elementor-widget elementor-widget-image" data-id="229647a" data-element_type="widget" data-widget_type="image.default">
				<div class="elementor-widget-container">
															<img loading="lazy" decoding="async" width="548" height="366" src="https://advena-bio.ae/wp-content/uploads/2024/09/11062b_5b382b8596004984a6f968191df5739amv2_d_7360_4912_s_4_2.jpg.webp" class="attachment-large size-large wp-image-6285" alt="" srcset="https://advena-bio.ae/wp-content/uploads/2024/09/11062b_5b382b8596004984a6f968191df5739amv2_d_7360_4912_s_4_2.jpg.webp 548w, https://advena-bio.ae/wp-content/uploads/2024/09/11062b_5b382b8596004984a6f968191df5739amv2_d_7360_4912_s_4_2.jpg-300x200.webp 300w, https://advena-bio.ae/wp-content/uploads/2024/09/11062b_5b382b8596004984a6f968191df5739amv2_d_7360_4912_s_4_2.jpg-360x240.webp 360w, https://advena-bio.ae/wp-content/uploads/2024/09/11062b_5b382b8596004984a6f968191df5739amv2_d_7360_4912_s_4_2.jpg-68x45.webp 68w" sizes="(max-width: 548px) 100vw, 548px" />															</div>
				</div>
				</div>
					</div>
				</div>
				</div>
		
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>iMSPR-Pro SPR system</title>
		<link>https://advena-bio.ae/shop/protein-analysis-biotechnology/spr/imspr-pro-spr-system/</link>
		
		<dc:creator><![CDATA[Hattorihanzo]]></dc:creator>
		<pubDate>Wed, 11 Sep 2024 11:15:08 +0000</pubDate>
				<guid isPermaLink="false">https://advena-bio.ae/?post_type=product&#038;p=6126</guid>

					<description><![CDATA[Automated sustainable SPR system for drug discovery and precise kinetics]]></description>
										<content:encoded><![CDATA[		<div data-elementor-type="wp-post" data-elementor-id="6425" class="elementor elementor-6425" data-elementor-post-type="ae_global_templates">
				<div class="elementor-element elementor-element-432b140 e-flex e-con-boxed e-con e-parent" data-id="432b140" data-element_type="container">
					<div class="e-con-inner">
				<div class="elementor-element elementor-element-b6f2580 elementor-widget elementor-widget-heading" data-id="b6f2580" data-element_type="widget" data-widget_type="heading.default">
				<div class="elementor-widget-container">
					<h3 class="elementor-heading-title elementor-size-default">Pro series common features</h3>				</div>
				</div>
					</div>
				</div>
		<div class="elementor-element elementor-element-0606ab6 e-flex e-con-boxed e-con e-parent" data-id="0606ab6" data-element_type="container">
					<div class="e-con-inner">
		<div class="elementor-element elementor-element-7ace4af e-con-full e-flex e-con e-child" data-id="7ace4af" data-element_type="container">
				<div class="elementor-element elementor-element-3024a49 elementor-widget elementor-widget-heading" data-id="3024a49" data-element_type="widget" data-widget_type="heading.default">
				<div class="elementor-widget-container">
					<h4 class="elementor-heading-title elementor-size-default">Sample to Answer 
</h4>				</div>
				</div>
				<div class="elementor-element elementor-element-ae66c9c elementor-widget elementor-widget-text-editor" data-id="ae66c9c" data-element_type="widget" data-widget_type="text-editor.default">
				<div class="elementor-widget-container">
									<p>After designing an experiment through the Experiment Wizard, when a sample is injected, the kinetics evaluation value can be obtained through the automatic analysis function built into the iMSPR operating software.</p>								</div>
				</div>
				</div>
		<div class="elementor-element elementor-element-b34dd45 e-con-full e-flex e-con e-child" data-id="b34dd45" data-element_type="container">
				<div class="elementor-element elementor-element-ee2757e elementor-widget elementor-widget-image" data-id="ee2757e" data-element_type="widget" data-widget_type="image.default">
				<div class="elementor-widget-container">
															<img loading="lazy" decoding="async" width="514" height="406" src="https://advena-bio.ae/wp-content/uploads/2024/09/Answer.png.webp" class="attachment-large size-large wp-image-6155" alt="" srcset="https://advena-bio.ae/wp-content/uploads/2024/09/Answer.png.webp 514w, https://advena-bio.ae/wp-content/uploads/2024/09/Answer.png-300x237.webp 300w" sizes="(max-width: 514px) 100vw, 514px" />															</div>
				</div>
				</div>
					</div>
				</div>
		<div class="elementor-element elementor-element-003598d e-flex e-con-boxed e-con e-parent" data-id="003598d" data-element_type="container">
					<div class="e-con-inner">
				<div class="elementor-element elementor-element-1fc0353 elementor-widget-divider--view-line elementor-widget elementor-widget-divider" data-id="1fc0353" data-element_type="widget" data-widget_type="divider.default">
				<div class="elementor-widget-container">
							<div class="elementor-divider">
			<span class="elementor-divider-separator">
						</span>
		</div>
						</div>
				</div>
		<div class="elementor-element elementor-element-61a3b6f e-con-full e-flex e-con e-child" data-id="61a3b6f" data-element_type="container">
				<div class="elementor-element elementor-element-6a20f02 elementor-widget elementor-widget-heading" data-id="6a20f02" data-element_type="widget" data-widget_type="heading.default">
				<div class="elementor-widget-container">
					<h4 class="elementor-heading-title elementor-size-default">Sustainable U-type fluidics module

</h4>				</div>
				</div>
				<div class="elementor-element elementor-element-799a86e elementor-widget elementor-widget-text-editor" data-id="799a86e" data-element_type="widget" data-widget_type="text-editor.default">
				<div class="elementor-widget-container">
									<div id="comp-lk7yui972" class="HcOXKn c9GqVL QxJLC3 lq2cno comp-lk7yui972 wixui-rich-text" data-testid="richTextElement"><p class="font_7 wixui-rich-text__text"><span class="wixui-rich-text__text">Through the U-type fluidics module, the immobilization step can be shortened efficiently, and referencing can be performed perfectly without time lag. In addition, it can be used permanently since it is manufactured with a PEEK unibody.</span></p></div><div id="comp-lk7yui984" class="MazNVa comp-lk7yui984 wixui-image"><div class="j7pOnl" data-testid="linkElement"> </div></div>								</div>
				</div>
				</div>
		<div class="elementor-element elementor-element-9441650 e-con-full e-flex e-con e-child" data-id="9441650" data-element_type="container">
				<div class="elementor-element elementor-element-bad0eea elementor-widget__width-initial elementor-absolute elementor-widget elementor-widget-icon-box" data-id="bad0eea" data-element_type="widget" data-settings="{&quot;_position&quot;:&quot;absolute&quot;}" data-widget_type="icon-box.default">
				<div class="elementor-widget-container">
							<div class="elementor-icon-box-wrapper">

			
						<div class="elementor-icon-box-content">

									<h3 class="elementor-icon-box-title">
						<span  >
							Inlet 2						</span>
					</h3>
				
									<p class="elementor-icon-box-description">
						When using both channels (binding analysis)					</p>
				
			</div>
			
		</div>
						</div>
				</div>
				<div class="elementor-element elementor-element-9267117 elementor-widget__width-initial elementor-absolute elementor-widget elementor-widget-icon-box" data-id="9267117" data-element_type="widget" data-settings="{&quot;_position&quot;:&quot;absolute&quot;}" data-widget_type="icon-box.default">
				<div class="elementor-widget-container">
							<div class="elementor-icon-box-wrapper">

			
						<div class="elementor-icon-box-content">

									<h3 class="elementor-icon-box-title">
						<span  >
							Inlet 1						</span>
					</h3>
				
									<p class="elementor-icon-box-description">
						When immobilizing the ligand					</p>
				
			</div>
			
		</div>
						</div>
				</div>
				<div class="elementor-element elementor-element-e022559 elementor-widget__width-initial elementor-absolute elementor-widget elementor-widget-icon-box" data-id="e022559" data-element_type="widget" data-settings="{&quot;_position&quot;:&quot;absolute&quot;}" data-widget_type="icon-box.default">
				<div class="elementor-widget-container">
							<div class="elementor-icon-box-wrapper">

			
						<div class="elementor-icon-box-content">

									<h3 class="elementor-icon-box-title">
						<span  >
							Outlet						</span>
					</h3>
				
				
			</div>
			
		</div>
						</div>
				</div>
				<div class="elementor-element elementor-element-5f8b385 elementor-widget elementor-widget-image" data-id="5f8b385" data-element_type="widget" data-widget_type="image.default">
				<div class="elementor-widget-container">
															<img loading="lazy" decoding="async" width="474" height="610" src="https://advena-bio.ae/wp-content/uploads/2024/09/U-type-fluidics3.png" class="attachment-large size-large wp-image-6158" alt="" srcset="https://advena-bio.ae/wp-content/uploads/2024/09/U-type-fluidics3.png 474w, https://advena-bio.ae/wp-content/uploads/2024/09/U-type-fluidics3-233x300.png 233w" sizes="(max-width: 474px) 100vw, 474px" />															</div>
				</div>
				</div>
					</div>
				</div>
		<div class="elementor-element elementor-element-9afd921 e-flex e-con-boxed e-con e-parent" data-id="9afd921" data-element_type="container">
					<div class="e-con-inner">
				<div class="elementor-element elementor-element-5767360 elementor-widget-divider--view-line elementor-widget elementor-widget-divider" data-id="5767360" data-element_type="widget" data-widget_type="divider.default">
				<div class="elementor-widget-container">
							<div class="elementor-divider">
			<span class="elementor-divider-separator">
						</span>
		</div>
						</div>
				</div>
		<div class="elementor-element elementor-element-9d77baa e-con-full e-flex e-con e-child" data-id="9d77baa" data-element_type="container">
				<div class="elementor-element elementor-element-fd1f666 elementor-widget elementor-widget-heading" data-id="fd1f666" data-element_type="widget" data-widget_type="heading.default">
				<div class="elementor-widget-container">
					<h4 class="elementor-heading-title elementor-size-default">Automatic qualification check of sensor chip
</h4>				</div>
				</div>
				<div class="elementor-element elementor-element-3c9146b elementor-widget elementor-widget-text-editor" data-id="3c9146b" data-element_type="widget" data-widget_type="text-editor.default">
				<div class="elementor-widget-container">
									<div id="comp-lk7yui972" class="HcOXKn c9GqVL QxJLC3 lq2cno comp-lk7yui972 wixui-rich-text" data-testid="richTextElement"><div id="comp-lk7yvyup1" class="HcOXKn c9GqVL QxJLC3 lq2cno comp-lk7yvyup1 wixui-rich-text" data-testid="richTextElement"><div id="comp-lk7z1zu5" class="HcOXKn c9GqVL QxJLC3 lq2cno comp-lk7z1zu5 wixui-rich-text" data-testid="richTextElement"><div id="comp-lk7yvyup1" class="HcOXKn c9GqVL QxJLC3 lq2cno comp-lk7yvyup1 wixui-rich-text" data-testid="richTextElement"><p class="font_7 wixui-rich-text__text"><span class="wixui-rich-text__text">The sensor chip status is checked before the experiment through the automatic check function built into the iMSPR operation software. You can secure more reliable data by checking initialization status.</span></p></div><div id="comp-lkalw2fv" class="MazNVa comp-lkalw2fv wixui-image"><div class="j7pOnl" data-testid="linkElement"> </div></div></div><div id="comp-lkam4jsn" class="HcOXKn c9GqVL QxJLC3 lq2cno comp-lkam4jsn wixui-rich-text" data-testid="richTextElement"> </div></div><div id="comp-lkalw2fv" class="MazNVa comp-lkalw2fv wixui-image"><div class="j7pOnl" data-testid="linkElement"> </div></div></div><div id="comp-lk7yui984" class="MazNVa comp-lk7yui984 wixui-image"><div class="j7pOnl" data-testid="linkElement"> </div></div>								</div>
				</div>
				</div>
		<div class="elementor-element elementor-element-94d1caa e-con-full e-flex e-con e-child" data-id="94d1caa" data-element_type="container">
				<div class="elementor-element elementor-element-af4e040 elementor-widget elementor-widget-image" data-id="af4e040" data-element_type="widget" data-widget_type="image.default">
				<div class="elementor-widget-container">
															<img loading="lazy" decoding="async" width="748" height="418" src="https://advena-bio.ae/wp-content/uploads/2024/09/chip-ckeck.png.webp" class="attachment-large size-large wp-image-6179" alt="" srcset="https://advena-bio.ae/wp-content/uploads/2024/09/chip-ckeck.png.webp 748w, https://advena-bio.ae/wp-content/uploads/2024/09/chip-ckeck.png-300x168.webp 300w, https://advena-bio.ae/wp-content/uploads/2024/09/chip-ckeck.png-600x335.webp 600w" sizes="(max-width: 748px) 100vw, 748px" />															</div>
				</div>
				</div>
					</div>
				</div>
		<div class="elementor-element elementor-element-f6cf618 e-flex e-con-boxed e-con e-parent" data-id="f6cf618" data-element_type="container">
					<div class="e-con-inner">
				<div class="elementor-element elementor-element-1274b4f elementor-widget-divider--view-line elementor-widget elementor-widget-divider" data-id="1274b4f" data-element_type="widget" data-widget_type="divider.default">
				<div class="elementor-widget-container">
							<div class="elementor-divider">
			<span class="elementor-divider-separator">
						</span>
		</div>
						</div>
				</div>
		<div class="elementor-element elementor-element-4d73a55 e-con-full e-flex e-con e-child" data-id="4d73a55" data-element_type="container">
				<div class="elementor-element elementor-element-d856b10 elementor-widget elementor-widget-heading" data-id="d856b10" data-element_type="widget" data-widget_type="heading.default">
				<div class="elementor-widget-container">
					<h4 class="elementor-heading-title elementor-size-default">In-line degassing system
</h4>				</div>
				</div>
				<div class="elementor-element elementor-element-6ca83bf elementor-widget elementor-widget-text-editor" data-id="6ca83bf" data-element_type="widget" data-widget_type="text-editor.default">
				<div class="elementor-widget-container">
									<div id="comp-lk7yui972" class="HcOXKn c9GqVL QxJLC3 lq2cno comp-lk7yui972 wixui-rich-text" data-testid="richTextElement"><div id="comp-lk7yvyup1" class="HcOXKn c9GqVL QxJLC3 lq2cno comp-lk7yvyup1 wixui-rich-text" data-testid="richTextElement"><div id="comp-lk7z1zu5" class="HcOXKn c9GqVL QxJLC3 lq2cno comp-lk7z1zu5 wixui-rich-text" data-testid="richTextElement"><p class="font_7 wixui-rich-text__text"><span class="wixui-rich-text__text">If you use the iMSPR Pro series, degassing the buffer is unnecessary. The built-in degassing module reduces the failure rate of experiments by removing bubbles.</span></p></div><div id="comp-lkam4jsn" class="HcOXKn c9GqVL QxJLC3 lq2cno comp-lkam4jsn wixui-rich-text" data-testid="richTextElement"> </div></div><div id="comp-lkalw2fv" class="MazNVa comp-lkalw2fv wixui-image"><div class="j7pOnl" data-testid="linkElement"> </div></div></div><div id="comp-lk7yui984" class="MazNVa comp-lk7yui984 wixui-image"><div class="j7pOnl" data-testid="linkElement"> </div></div>								</div>
				</div>
				</div>
		<div class="elementor-element elementor-element-61c6dba e-con-full e-flex e-con e-child" data-id="61c6dba" data-element_type="container">
				<div class="elementor-element elementor-element-1d73ae2 elementor-widget elementor-widget-image" data-id="1d73ae2" data-element_type="widget" data-widget_type="image.default">
				<div class="elementor-widget-container">
															<img loading="lazy" decoding="async" width="582" height="364" src="https://advena-bio.ae/wp-content/uploads/2024/09/Снимок-экрана-2024-09-12-в-18.07.46.png" class="attachment-large size-large wp-image-6197" alt="" srcset="https://advena-bio.ae/wp-content/uploads/2024/09/Снимок-экрана-2024-09-12-в-18.07.46.png 582w, https://advena-bio.ae/wp-content/uploads/2024/09/Снимок-экрана-2024-09-12-в-18.07.46-300x188.png 300w" sizes="(max-width: 582px) 100vw, 582px" />															</div>
				</div>
				</div>
					</div>
				</div>
		<div class="elementor-element elementor-element-87816bd elementor-hidden-mobile e-flex e-con-boxed e-con e-parent" data-id="87816bd" data-element_type="container">
					<div class="e-con-inner">
				<div class="elementor-element elementor-element-9794b8c elementor-widget-divider--view-line elementor-widget elementor-widget-divider" data-id="9794b8c" data-element_type="widget" data-widget_type="divider.default">
				<div class="elementor-widget-container">
							<div class="elementor-divider">
			<span class="elementor-divider-separator">
						</span>
		</div>
						</div>
				</div>
				<div class="elementor-element elementor-element-8a1d593 elementor-widget elementor-widget-heading" data-id="8a1d593" data-element_type="widget" data-widget_type="heading.default">
				<div class="elementor-widget-container">
					<h3 class="elementor-heading-title elementor-size-default">What are the differences between iMSPR Pro Series
</h3>				</div>
				</div>
		<div class="elementor-element elementor-element-3f31624 e-grid e-con-full e-con e-child" data-id="3f31624" data-element_type="container">
				<div class="elementor-element elementor-element-dba678d elementor-widget elementor-widget-heading" data-id="dba678d" data-element_type="widget" data-widget_type="heading.default">
				<div class="elementor-widget-container">
					<h4 class="elementor-heading-title elementor-size-default">.</h4>				</div>
				</div>
				<div class="elementor-element elementor-element-8c680ad elementor-widget elementor-widget-heading" data-id="8c680ad" data-element_type="widget" data-widget_type="heading.default">
				<div class="elementor-widget-container">
					<h4 class="elementor-heading-title elementor-size-default">Pro2X</h4>				</div>
				</div>
				<div class="elementor-element elementor-element-859ad1a elementor-widget elementor-widget-heading" data-id="859ad1a" data-element_type="widget" data-widget_type="heading.default">
				<div class="elementor-widget-container">
					<h4 class="elementor-heading-title elementor-size-default">ProX</h4>				</div>
				</div>
				<div class="elementor-element elementor-element-4298449 elementor-widget elementor-widget-heading" data-id="4298449" data-element_type="widget" data-widget_type="heading.default">
				<div class="elementor-widget-container">
					<h4 class="elementor-heading-title elementor-size-default">Pro</h4>				</div>
				</div>
				<div class="elementor-element elementor-element-006c858 elementor-widget elementor-widget-heading" data-id="006c858" data-element_type="widget" data-widget_type="heading.default">
				<div class="elementor-widget-container">
					<h3 class="elementor-heading-title elementor-size-default">Sample flow channel</h3>				</div>
				</div>
				<div class="elementor-element elementor-element-6c0b405 elementor-widget elementor-widget-icon-box" data-id="6c0b405" data-element_type="widget" data-widget_type="icon-box.default">
				<div class="elementor-widget-container">
							<div class="elementor-icon-box-wrapper">

			
						<div class="elementor-icon-box-content">

									<h3 class="elementor-icon-box-title">
						<span  >
							4						</span>
					</h3>
				
									<p class="elementor-icon-box-description">
						two experiments per chip					</p>
				
			</div>
			
		</div>
						</div>
				</div>
				<div class="elementor-element elementor-element-6635361 elementor-widget elementor-widget-icon-box" data-id="6635361" data-element_type="widget" data-widget_type="icon-box.default">
				<div class="elementor-widget-container">
							<div class="elementor-icon-box-wrapper">

			
						<div class="elementor-icon-box-content">

									<h3 class="elementor-icon-box-title">
						<span  >
							4						</span>
					</h3>
				
									<p class="elementor-icon-box-description">
						one experiment per chip
					</p>
				
			</div>
			
		</div>
						</div>
				</div>
				<div class="elementor-element elementor-element-d93763a elementor-widget elementor-widget-icon-box" data-id="d93763a" data-element_type="widget" data-widget_type="icon-box.default">
				<div class="elementor-widget-container">
							<div class="elementor-icon-box-wrapper">

			
						<div class="elementor-icon-box-content">

									<h3 class="elementor-icon-box-title">
						<span  >
							2						</span>
					</h3>
				
									<p class="elementor-icon-box-description">
						one experiment per chip					</p>
				
			</div>
			
		</div>
						</div>
				</div>
				<div class="elementor-element elementor-element-bb32320 elementor-widget elementor-widget-heading" data-id="bb32320" data-element_type="widget" data-widget_type="heading.default">
				<div class="elementor-widget-container">
					<h3 class="elementor-heading-title elementor-size-default">Fluidics module
</h3>				</div>
				</div>
				<div class="elementor-element elementor-element-30662ea elementor-position-top elementor-position-top elementor-widget elementor-widget-image-box" data-id="30662ea" data-element_type="widget" data-widget_type="image-box.default">
				<div class="elementor-widget-container">
					<div class="elementor-image-box-wrapper"><figure class="elementor-image-box-img"><img loading="lazy" decoding="async" width="110" height="102" src="https://advena-bio.ae/wp-content/uploads/2024/09/0eb00b_4ee1f8d268d3465e876911ee48a804d6mv2.png.webp" class="attachment-full size-full wp-image-6218" alt="" /></figure><div class="elementor-image-box-content"><p class="elementor-image-box-description">UFD Fluidics module with dual U-type flow cells 
</p></div></div>				</div>
				</div>
				<div class="elementor-element elementor-element-a386285 elementor-position-top elementor-position-top elementor-widget elementor-widget-image-box" data-id="a386285" data-element_type="widget" data-widget_type="image-box.default">
				<div class="elementor-widget-container">
					<div class="elementor-image-box-wrapper"><figure class="elementor-image-box-img"><img loading="lazy" decoding="async" width="110" height="102" src="https://advena-bio.ae/wp-content/uploads/2024/09/1xutype.png.webp" class="attachment-full size-full wp-image-6219" alt="" /></figure><div class="elementor-image-box-content"><p class="elementor-image-box-description">Standard Fluidics module with mono U-type flow cells 
</p></div></div>				</div>
				</div>
				<div class="elementor-element elementor-element-fc2d328 elementor-position-top elementor-position-top elementor-widget elementor-widget-image-box" data-id="fc2d328" data-element_type="widget" data-widget_type="image-box.default">
				<div class="elementor-widget-container">
					<div class="elementor-image-box-wrapper"><figure class="elementor-image-box-img"><img loading="lazy" decoding="async" width="110" height="102" src="https://advena-bio.ae/wp-content/uploads/2024/09/1xutype.png.webp" class="attachment-full size-full wp-image-6219" alt="" /></figure><div class="elementor-image-box-content"><p class="elementor-image-box-description">Standard Fluidics module with mono U-type flow cells 
</p></div></div>				</div>
				</div>
				<div class="elementor-element elementor-element-44f2ba7 elementor-widget elementor-widget-heading" data-id="44f2ba7" data-element_type="widget" data-widget_type="heading.default">
				<div class="elementor-widget-container">
					<h3 class="elementor-heading-title elementor-size-default">Sample injection</h3>				</div>
				</div>
				<div class="elementor-element elementor-element-aa18e42 elementor-position-top elementor-position-top elementor-widget elementor-widget-image-box" data-id="aa18e42" data-element_type="widget" data-widget_type="image-box.default">
				<div class="elementor-widget-container">
					<div class="elementor-image-box-wrapper"><figure class="elementor-image-box-img"><img loading="lazy" decoding="async" width="108" height="136" src="https://advena-bio.ae/wp-content/uploads/2024/09/0eb00b_b9e220ff478f402a8e715e8537284a30mv2.png.webp" class="attachment-full size-full wp-image-6220" alt="" /></figure><div class="elementor-image-box-content"><h3 class="elementor-image-box-title">Autosampler with dual injection valve</h3><p class="elementor-image-box-description">48 vials rack x 2<br>
96 well plate x 2</p></div></div>				</div>
				</div>
				<div class="elementor-element elementor-element-2541539 elementor-position-top elementor-position-top elementor-widget elementor-widget-image-box" data-id="2541539" data-element_type="widget" data-widget_type="image-box.default">
				<div class="elementor-widget-container">
					<div class="elementor-image-box-wrapper"><figure class="elementor-image-box-img"><img loading="lazy" decoding="async" width="108" height="136" src="https://advena-bio.ae/wp-content/uploads/2024/09/0eb00b_b9e220ff478f402a8e715e8537284a30mv2.png.webp" class="attachment-full size-full wp-image-6220" alt="" /></figure><div class="elementor-image-box-content"><h3 class="elementor-image-box-title">Autosampler with mono injection valve</h3><p class="elementor-image-box-description">48 vials rack x 2<br>
96 well plate x 2</p></div></div>				</div>
				</div>
				<div class="elementor-element elementor-element-4e89558 elementor-position-top elementor-position-top elementor-widget elementor-widget-image-box" data-id="4e89558" data-element_type="widget" data-widget_type="image-box.default">
				<div class="elementor-widget-container">
					<div class="elementor-image-box-wrapper"><figure class="elementor-image-box-img"><img loading="lazy" decoding="async" width="140" height="138" src="https://advena-bio.ae/wp-content/uploads/2024/09/Снимок-экрана-2024-09-13-в-10.56.02.png" class="attachment-full size-full wp-image-6221" alt="" srcset="https://advena-bio.ae/wp-content/uploads/2024/09/Снимок-экрана-2024-09-13-в-10.56.02.png 140w, https://advena-bio.ae/wp-content/uploads/2024/09/Снимок-экрана-2024-09-13-в-10.56.02-100x100.png 100w" sizes="(max-width: 140px) 100vw, 140px" /></figure><div class="elementor-image-box-content"><h3 class="elementor-image-box-title">One by one</h3></div></div>				</div>
				</div>
				<div class="elementor-element elementor-element-2d363e8 elementor-widget elementor-widget-heading" data-id="2d363e8" data-element_type="widget" data-widget_type="heading.default">
				<div class="elementor-widget-container">
					<h3 class="elementor-heading-title elementor-size-default">Sample volume
(200ul sample loop)</h3>				</div>
				</div>
				<div class="elementor-element elementor-element-ccb8c35 elementor-widget elementor-widget-icon-box" data-id="ccb8c35" data-element_type="widget" data-widget_type="icon-box.default">
				<div class="elementor-widget-container">
							<div class="elementor-icon-box-wrapper">

			
						<div class="elementor-icon-box-content">

				
									<p class="elementor-icon-box-description">
						Max 200ul
Partial injection available
30 ~ 75 ul dead volume					</p>
				
			</div>
			
		</div>
						</div>
				</div>
				<div class="elementor-element elementor-element-c1d3884 elementor-widget elementor-widget-icon-box" data-id="c1d3884" data-element_type="widget" data-widget_type="icon-box.default">
				<div class="elementor-widget-container">
							<div class="elementor-icon-box-wrapper">

			
						<div class="elementor-icon-box-content">

				
									<p class="elementor-icon-box-description">
						Max 200ul
Partial injection available
30 ~ 75 ul dead volume					</p>
				
			</div>
			
		</div>
						</div>
				</div>
				<div class="elementor-element elementor-element-59f806a elementor-widget elementor-widget-icon-box" data-id="59f806a" data-element_type="widget" data-widget_type="icon-box.default">
				<div class="elementor-widget-container">
							<div class="elementor-icon-box-wrapper">

			
						<div class="elementor-icon-box-content">

				
									<p class="elementor-icon-box-description">
						Max 200ul
Partial injection available
30 ~ 60 ul dead volume					</p>
				
			</div>
			
		</div>
						</div>
				</div>
				<div class="elementor-element elementor-element-ed7576e elementor-widget elementor-widget-heading" data-id="ed7576e" data-element_type="widget" data-widget_type="heading.default">
				<div class="elementor-widget-container">
					<h3 class="elementor-heading-title elementor-size-default">Screening capacity</h3>				</div>
				</div>
				<div class="elementor-element elementor-element-9607344 elementor-widget elementor-widget-icon-box" data-id="9607344" data-element_type="widget" data-widget_type="icon-box.default">
				<div class="elementor-widget-container">
							<div class="elementor-icon-box-wrapper">

			
						<div class="elementor-icon-box-content">

				
									<p class="elementor-icon-box-description">
						300 samples per day					</p>
				
			</div>
			
		</div>
						</div>
				</div>
				<div class="elementor-element elementor-element-f9b43f0 elementor-widget elementor-widget-icon-box" data-id="f9b43f0" data-element_type="widget" data-widget_type="icon-box.default">
				<div class="elementor-widget-container">
							<div class="elementor-icon-box-wrapper">

			
						<div class="elementor-icon-box-content">

				
									<p class="elementor-icon-box-description">
						150 samples per day					</p>
				
			</div>
			
		</div>
						</div>
				</div>
				<div class="elementor-element elementor-element-07cc0cd elementor-widget elementor-widget-icon-box" data-id="07cc0cd" data-element_type="widget" data-widget_type="icon-box.default">
				<div class="elementor-widget-container">
							<div class="elementor-icon-box-wrapper">

			
						<div class="elementor-icon-box-content">

				
									<p class="elementor-icon-box-description">
						Not recommended					</p>
				
			</div>
			
		</div>
						</div>
				</div>
				</div>
					</div>
				</div>
		<div class="elementor-element elementor-element-1ff39cd e-flex e-con-boxed e-con e-parent" data-id="1ff39cd" data-element_type="container">
					<div class="e-con-inner">
				<div class="elementor-element elementor-element-7e055e2 elementor-widget-divider--view-line elementor-widget elementor-widget-divider" data-id="7e055e2" data-element_type="widget" data-widget_type="divider.default">
				<div class="elementor-widget-container">
							<div class="elementor-divider">
			<span class="elementor-divider-separator">
						</span>
		</div>
						</div>
				</div>
				<div class="elementor-element elementor-element-1de042f elementor-widget elementor-widget-heading" data-id="1de042f" data-element_type="widget" data-widget_type="heading.default">
				<div class="elementor-widget-container">
					<h3 class="elementor-heading-title elementor-size-default">Add options,
get powerful functions</h3>				</div>
				</div>
					</div>
				</div>
		<div class="elementor-element elementor-element-d797bf5 e-flex e-con-boxed e-con e-parent" data-id="d797bf5" data-element_type="container">
					<div class="e-con-inner">
		<div class="elementor-element elementor-element-f2f9cc8 e-con-full e-flex e-con e-child" data-id="f2f9cc8" data-element_type="container">
				<div class="elementor-element elementor-element-4367e6c elementor-widget elementor-widget-heading" data-id="4367e6c" data-element_type="widget" data-widget_type="heading.default">
				<div class="elementor-widget-container">
					<h4 class="elementor-heading-title elementor-size-default">Temperature control unit

</h4>				</div>
				</div>
				<div class="elementor-element elementor-element-6b15ebb elementor-widget elementor-widget-text-editor" data-id="6b15ebb" data-element_type="widget" data-widget_type="text-editor.default">
				<div class="elementor-widget-container">
									<p><span class="wixui-rich-text__text"><span class="color_15 wixui-rich-text__text">In various temperature environments (10 to 40 degrees, room temperature dependent conditions), it is possible to obtain the value of the bonding properties and obtain the thermodynamic constants (enthalpy, entropy) through this. as well as biological temperature</span></span><span class="wixui-rich-text__text"><span class="color_15 wixui-rich-text__text">The binding properties of new drug candidates can be confirmed in the environment (37 degrees). </span></span><span class="wixui-rich-text__text"><span class="color_15 wixui-rich-text__text">Through this, predict the dynamics of the drug​ in the body and understand the bonding between molecules more completely.</span></span></p>								</div>
				</div>
				</div>
		<div class="elementor-element elementor-element-3c84ec2 e-con-full e-flex e-con e-child" data-id="3c84ec2" data-element_type="container">
				<div class="elementor-element elementor-element-ff2bcb5 elementor-widget elementor-widget-heading" data-id="ff2bcb5" data-element_type="widget" data-widget_type="heading.default">
				<div class="elementor-widget-container">
					<h4 class="elementor-heading-title elementor-size-default">Cooling unit

</h4>				</div>
				</div>
				<div class="elementor-element elementor-element-1c7f09b elementor-widget elementor-widget-text-editor" data-id="1c7f09b" data-element_type="widget" data-widget_type="text-editor.default">
				<div class="elementor-widget-container">
									<p>When a large amount of sample needs to be analyzed, drug candidates such as antibodies may be denatured due to the high temperature inside the autosampler. The cooling unit is a temperature cooling function inside the autosampler that can prevent this. It can cool down to 4 degrees, so you can safely analyze your samples until the end. </p>								</div>
				</div>
				</div>
					</div>
				</div>
		<div class="elementor-element elementor-element-a84bea1 e-flex e-con-boxed e-con e-parent" data-id="a84bea1" data-element_type="container">
					<div class="e-con-inner">
		<div class="elementor-element elementor-element-e17f69e e-con-full e-flex e-con e-child" data-id="e17f69e" data-element_type="container">
				<div class="elementor-element elementor-element-5ae2662 elementor-widget elementor-widget-heading" data-id="5ae2662" data-element_type="widget" data-widget_type="heading.default">
				<div class="elementor-widget-container">
					<h4 class="elementor-heading-title elementor-size-default">GxP Program
</h4>				</div>
				</div>
				<div class="elementor-element elementor-element-73d8f99 elementor-widget elementor-widget-text-editor" data-id="73d8f99" data-element_type="widget" data-widget_type="text-editor.default">
				<div class="elementor-widget-container">
									<p>21 CFR compliance compliant programs can be installed. </p>								</div>
				</div>
				</div>
		<div class="elementor-element elementor-element-811cb35 e-con-full e-flex e-con e-child" data-id="811cb35" data-element_type="container">
				<div class="elementor-element elementor-element-a1c316a elementor-widget elementor-widget-heading" data-id="a1c316a" data-element_type="widget" data-widget_type="heading.default">
				<div class="elementor-widget-container">
					<h4 class="elementor-heading-title elementor-size-default">Premium maintenance program


</h4>				</div>
				</div>
				<div class="elementor-element elementor-element-0e68e65 elementor-widget elementor-widget-text-editor" data-id="0e68e65" data-element_type="widget" data-widget_type="text-editor.default">
				<div class="elementor-widget-container">
									<div id="comp-lkaqzzy4" class="HcOXKn c9GqVL QxJLC3 lq2cno comp-lkaqzzy4 wixui-rich-text" data-testid="richTextElement"><p class="font_8 wixui-rich-text__text"><span class="wixui-rich-text__text">If you upgrade to iMcare+, a premium maintenance/management program, you can extend the warranty period to 2 years, as well as receive regular inspection, SW upgrade, free replacement of consumables and free operation training for 10 years.</span></p></div><div id="comp-lkar1ptl" class="MazNVa comp-lkar1ptl wixui-image"><div class="j7pOnl" data-testid="linkElement"> </div></div>								</div>
				</div>
				</div>
					</div>
				</div>
				</div>
		
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>iMSPR Sensor Chips and reagents</title>
		<link>https://advena-bio.ae/shop/protein-analysis-biotechnology/spr/imspr-sensor-chips-and-reagents/</link>
		
		<dc:creator><![CDATA[Hattorihanzo]]></dc:creator>
		<pubDate>Wed, 11 Sep 2024 07:09:26 +0000</pubDate>
				<guid isPermaLink="false">https://advena-bio.ae/?post_type=product&#038;p=6076</guid>

					<description><![CDATA[Icluebio provides a wide range of sensor chip surfaces (types, functionalities, densities, and thicknesses), as well as different types of immobilization reagents, to be applied to various applications.]]></description>
										<content:encoded><![CDATA[<p>The sensor chip surface must be selected correctly according to various conditions such as analyte type, analyte size, ligand immobilization method, and non-specific adsorption.</p>
<div class="" data-mesh-id="comp-lkem7zsvinlineContent" data-testid="inline-content">
<div data-mesh-id="comp-lkem7zsvinlineContent-gridContainer" data-testid="mesh-container-content">
<div id="comp-lkkhqmju" class="comp-lkkhqmju SPY_vo">
<div class="" data-mesh-id="comp-lkkhqmjuinlineContent" data-testid="inline-content">
<div data-mesh-id="comp-lkkhqmjuinlineContent-gridContainer" data-testid="mesh-container-content">
<div id="comp-lkemkxys" class="HcOXKn c9GqVL QxJLC3 lq2cno comp-lkemkxys wixui-rich-text" data-testid="richTextElement">
<h2 class="font_8 wixui-rich-text__text"><strong><span class="wixui-rich-text__text">Alkanthiols based planar sensor chips</span></strong></h2>
</div>
<div id="comp-lkemkxyt2" class="HcOXKn c9GqVL QxJLC3 lq2cno comp-lkemkxyt2 wixui-rich-text" data-testid="richTextElement">
<p class="font_8 wixui-rich-text__text"><span class="color_15 wixui-rich-text__text"><span class="wixui-rich-text__text">Since the iMSPR system has sufficient sensitivity, satisfactory results can be obtained even on a sensor chip (Planar Au sensor chip) formed with a monolayer of linker material that can immobilize the ligand in the case of a molecule with a relatively large size (about 5 kDa or more) – protein, cell, bacteria, virus, exosome, etc. In particular, in the case of antibody drugs, it is a very suitable application field because the signal is large and the affinity is high.</span></span></p>
<h2 class="font_8 wixui-rich-text__text"><strong><span class="wixui-rich-text__text"><span class="color_15 wixui-rich-text__text">Structure</span></span></strong></h2>
<p><img loading="lazy" decoding="async" class="alignnone wp-image-6099 " src="https://advena-bio.ae/wp-content/uploads/2024/09/Planar-sensor-chip.png-2.webp" alt="" width="749" height="323" srcset="https://advena-bio.ae/wp-content/uploads/2024/09/Planar-sensor-chip.png-2.webp 886w, https://advena-bio.ae/wp-content/uploads/2024/09/Planar-sensor-chip.png-2-300x129.webp 300w, https://advena-bio.ae/wp-content/uploads/2024/09/Planar-sensor-chip.png-2-768x331.webp 768w, https://advena-bio.ae/wp-content/uploads/2024/09/Planar-sensor-chip.png-2-600x259.webp 600w" sizes="(max-width: 749px) 100vw, 749px" /></p>
<div id="comp-lkemkxyy6" class="HcOXKn c9GqVL QxJLC3 lq2cno comp-lkemkxyy6 wixui-rich-text" data-testid="richTextElement">
<p>&nbsp;</p>
<p class="font_8 wixui-rich-text__text"><strong><span class="wixui-rich-text__text"><span class="color_15 wixui-rich-text__text">Immobilization level (Max.)</span></span></strong></p>
</div>
<div id="comp-lkemkxyz5" class="HcOXKn c9GqVL QxJLC3 lq2cno comp-lkemkxyz5 wixui-rich-text" data-testid="richTextElement">
<p class="font_8 wixui-rich-text__text"><span class="wixui-rich-text__text"><span class="color_15 wixui-rich-text__text">100 ~ 2000 RU (molecule type and MW dependent)</span></span></p>
<div id="comp-lkemjial" class="HcOXKn c9GqVL QxJLC3 lq2cno comp-lkemjial wixui-rich-text" data-testid="richTextElement">
<h2 class="font_8 wixui-rich-text__text"><strong><span class="wixui-rich-text__text">Dextran based membrane sensor chips</span></strong></h2>
</div>
<div id="comp-lkemjias1" class="HcOXKn c9GqVL QxJLC3 lq2cno comp-lkemjias1 wixui-rich-text" data-testid="richTextElement">
<p class="font_8 wixui-rich-text__text"><span class="wixui-rich-text__text"><span class="color_15 wixui-rich-text__text">Dextran sensor chips were first commercially available in the early 1990s by applying solid surface technology well-optimized for affinity chromatography. Therefore, the largest amount of data has been accumulated using SPR to date. Therefore, there are many literatures and results that can be referenced, which is very advantageous for reproducing similar experiments. It is a universal sensor chip that can be used from large-sized proteins to small compounds.</span></span></p>
<h2 class="font_8 wixui-rich-text__text"><strong><span class="wixui-rich-text__text"><span class="color_15 wixui-rich-text__text">Structure</span></span></strong></h2>
<p>&nbsp;</p>
<p><img loading="lazy" decoding="async" class="alignnone size-large wp-image-6098" src="https://advena-bio.ae/wp-content/uploads/2024/09/Dextran-sensor-chip.png-1024x403.webp" alt="" width="800" height="315" srcset="https://advena-bio.ae/wp-content/uploads/2024/09/Dextran-sensor-chip.png-1024x403.webp 1024w, https://advena-bio.ae/wp-content/uploads/2024/09/Dextran-sensor-chip.png-300x118.webp 300w, https://advena-bio.ae/wp-content/uploads/2024/09/Dextran-sensor-chip.png-768x302.webp 768w, https://advena-bio.ae/wp-content/uploads/2024/09/Dextran-sensor-chip.png-600x236.webp 600w, https://advena-bio.ae/wp-content/uploads/2024/09/Dextran-sensor-chip.png.webp 1260w" sizes="(max-width: 800px) 100vw, 800px" /></p>
<div id="comp-lkemjib5" class="HcOXKn c9GqVL QxJLC3 lq2cno comp-lkemjib5 wixui-rich-text" data-testid="richTextElement">
<p>&nbsp;</p>
<p class="font_8 wixui-rich-text__text"><strong><span class="wixui-rich-text__text"><span class="color_15 wixui-rich-text__text">Immobilization level (Max.)</span></span></strong></p>
</div>
<div id="comp-lkemjib62" class="HcOXKn c9GqVL QxJLC3 lq2cno comp-lkemjib62 wixui-rich-text" data-testid="richTextElement">
<p class="font_8 wixui-rich-text__text"><span class="wixui-rich-text__text"><span class="color_15 wixui-rich-text__text">1000 ~ 10000 RU (molecule type and MW dependent)</span></span></p>
<div id="comp-lkemctyb2" class="HcOXKn c9GqVL QxJLC3 lq2cno comp-lkemctyb2 wixui-rich-text" data-testid="richTextElement">
<h2 class="font_8 wixui-rich-text__text"><span class="wixui-rich-text__text">Linear polymer based membrane sensor chips</span></h2>
</div>
<div id="comp-lkemctyd" class="HcOXKn c9GqVL QxJLC3 lq2cno comp-lkemctyd wixui-rich-text" data-testid="richTextElement">
<p class="font_8 wixui-rich-text__text"><span class="wixui-rich-text__text"><span class="color_15 wixui-rich-text__text">The linear polymer sensor chip developed this time is a sensor chip that complements the shortcomings of the dextran sensor chip while maintaining the performance of the membrane sensor chip. It can be fabricated more reproducibly, exhibits a higher signal-to-noise ratio, improves diffusion properties and reduces non-specific adsorption. A representative sensor chip is the HC1000. It is a sensor chip suitable for analyzing small molecular compounds.</span></span></p>
<h2 class="font_8 wixui-rich-text__text"><strong><span class="wixui-rich-text__text"><span class="color_15 wixui-rich-text__text">Structure</span></span></strong></h2>
<p><img loading="lazy" decoding="async" class="alignnone wp-image-6103" src="https://advena-bio.ae/wp-content/uploads/2024/09/HC-sensor-chip.png.webp" alt="" width="776" height="484" srcset="https://advena-bio.ae/wp-content/uploads/2024/09/HC-sensor-chip.png.webp 888w, https://advena-bio.ae/wp-content/uploads/2024/09/HC-sensor-chip.png-300x187.webp 300w, https://advena-bio.ae/wp-content/uploads/2024/09/HC-sensor-chip.png-768x479.webp 768w, https://advena-bio.ae/wp-content/uploads/2024/09/HC-sensor-chip.png-600x374.webp 600w" sizes="(max-width: 776px) 100vw, 776px" /></p>
<div id="comp-lkemjib5" class="HcOXKn c9GqVL QxJLC3 lq2cno comp-lkemjib5 wixui-rich-text" data-testid="richTextElement">
<p>&nbsp;</p>
<p class="font_8 wixui-rich-text__text"><strong><span class="wixui-rich-text__text"><span class="color_15 wixui-rich-text__text">Immobilization level (Max.)</span></span></strong></p>
</div>
<div id="comp-lkemjib62" class="HcOXKn c9GqVL QxJLC3 lq2cno comp-lkemjib62 wixui-rich-text" data-testid="richTextElement">
<p class="font_8 wixui-rich-text__text"><span class="wixui-rich-text__text"><span class="color_15 wixui-rich-text__text">1000 ~ 20000 RU (molecule type and MW dependent)</span></span></p>
<div id="comp-lkhxyp07" class="HcOXKn c9GqVL QxJLC3 lq2cno comp-lkhxyp07 wixui-rich-text" data-testid="richTextElement">
<h2 class="font_8 wixui-rich-text__text"><span class="wixui-rich-text__text">Contact angle comparison</span></h2>
</div>
<div id="comp-lkhxyp082" class="HcOXKn c9GqVL QxJLC3 lq2cno comp-lkhxyp082 wixui-rich-text" data-testid="richTextElement">
<p class="font_8 wixui-rich-text__text"><span class="wixui-rich-text__text">Sensor chips have different degrees of hydrophilicity depending on the backborn material structure. Instead of using just one chip, improve the quality of your analysis with sensor chips of various surfaces.</span></p>
<div id="comp-lkcmjimf" class="HcOXKn c9GqVL QxJLC3 lq2cno comp-lkcmjimf wixui-rich-text" data-testid="richTextElement">
<h2 class="font_8 wixui-rich-text__text"><strong><span class="wixui-rich-text__text">Sensor chip storage kit</span></strong></h2>
</div>
<div id="comp-lkcmkn8m" class="HcOXKn c9GqVL QxJLC3 lq2cno comp-lkcmkn8m wixui-rich-text" data-testid="richTextElement">
<p class="font_8 wixui-rich-text__text"><span class="wixui-rich-text__text">It is an essential tool to keep your sensor chip running. After removing the used prism holder from the device, install the s-type fluidics module. Then fill with storage buffer and store in the refrigerator. The ligand material immobilized on the sensor chip can be safely stored until the next use.</span></p>
</div>
</div>
</div>
</div>
</div>
</div>
</div>
</div>
</div>
</div>
</div>
</div>
</div>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>SA3800™ Spectral Analyzer</title>
		<link>https://advena-bio.ae/shop/cell-biology/flow-cytometry/sa3800-spectral-analyzer/</link>
		
		<dc:creator><![CDATA[Hattorihanzo]]></dc:creator>
		<pubDate>Thu, 29 Aug 2024 07:33:17 +0000</pubDate>
				<guid isPermaLink="false">https://advena-bio.ae/?post_type=product&#038;p=5774</guid>

					<description><![CDATA[<p class="p1">SA3800 spectral flow cytometer features ease-of-use, automation and spectral technology to optimize sensitivity and simplify workflow</p>]]></description>
										<content:encoded><![CDATA[<p class="p1"><b>Sony SA3800 Spectral Cell Analyzer: Revolutionizing Cellular Analysis</b></p>
<p class="p1">The Sony SA3800 spectral cell analyzer represents a groundbreaking advancement in flow cytometry, integrating sophisticated electronics and patented optical technologies to deliver exceptional analytical performance. Designed to streamline the entire workflow, from instrument startup to system maintenance, the SA3800 offers unparalleled automation and simplicity, making it suitable for both seasoned experts and newcomers to flow cytometry.</p>
<p class="p1"><b>Advanced Spectral Technology</b></p>
<p class="p1">At the core of the SA3800’s capabilities is its spectral analysis technology, which significantly enhances sensitivity and facilitates the detection of dim signals. By capturing photons across a broad wavelength range from 420 nm to 800 nm, the SA3800 optimizes the detection of fluorescent signals. This spectral approach not only improves sensitivity but also simplifies the design and analysis of multicolor applications. Unlike traditional flow cytometers that rely on color compensation to subtract overlapping fluorescence, the SA3800 employs spectral unmixing. This method combines the fluorescence data from all channels and then mathematically separates the colors, yielding clearer and more accurate data. This process simplifies workflow, improves the visualization of autofluorescence, and enhances overall data quality.</p>
<p class="p1"><b>Innovative Optical Technologies</b></p>
<p class="p1">The SA3800 features a unique prism-based collection system that directs emitted light to a 32-channel photomultiplier tube (PMT). This setup allows for the detection of 34 data points, capturing a comprehensive spectral fingerprint of each fluorochrome. The result is precise and accurate visualizations of fluorescent populations, providing researchers with detailed information about each marker’s spectral characteristics.</p>
<p class="p1"><b>Spectral Unmixing</b></p>
<p class="p1">One of the standout features of the SA3800 is its ability to perform spectral unmixing. This powerful capability allows for the separation of overlapping fluorophores into pure signals, enabling more accurate measurement of each fluorochrome. Unlike conventional systems where overlapping signals can obscure data, spectral unmixing captures the full range of emitted photons, enhancing the detection of dim signals and rare populations. This technique also effectively handles autofluorescence by isolating and subtracting it from the signal, resulting in cleaner and more reliable data.</p>
<p class="p1"><b>Automated Workflow</b></p>
<p class="p1">Automation is a key aspect of the SA3800, ensuring a streamlined and accurate workflow. The system is designed to handle a variety of standard and deep-well plates, as well as 12 x 75-mm 5-mL tubes. The novel 3D AutoSampler technology further enhances efficiency by moving the sample plate in both horizontal and vertical directions. This reduces sample-to-sample cross-contamination and speeds up cleaning processes. The fixed probe, combined with sensors that calculate the height of the sample container and automatically adjust for any contact, minimizes the risk of cross-contamination and flow problems, ensuring a reliable and consistent sample acquisition process.</p>
<p class="p1"><b>User-Friendly Software</b></p>
<p class="p1">The SA3800 is equipped with intuitive software that simplifies every aspect of operation. From setup and panel design to data acquisition and analysis, the software provides step-by-step guidance. The user interface allows for customization of instrument settings and experiment configurations, accommodating both novice and experienced users. Key features include the Experimental Designer, which assists in creating experiments, and the Spectral Library, which facilitates the management of reagent data for future use.</p>
<p class="p1"><b>System Standardization</b></p>
<p class="p1">The SA3800 includes a novel standardization feature that automatically sets the system to a master specification with a single click. This function eliminates variability between instruments, ensuring consistent and reliable results across different setups and locations. By reducing the potential for setup subjectivity, the standardization mode supports collaborative research and long-term studies, providing accurate and reproducible data regardless of operator experience.</p>
<p class="p1"><b>Efficient Sample Acquisition and Analysis</b></p>
<p class="p1">The system’s software supports a range of acquisition functions, including the ability to control instrument settings and adjust acquisition speeds. The Walk Away Event Checker monitors the integrity of the sample stream, detecting issues such as air bubbles or low event rates, and can automatically clear clogs or continue to the next sample. The Autofluorescence Finder feature helps identify and subtract autofluorescent signals, ensuring that researchers obtain accurate representations of their fluorescent populations.</p>
<p class="p1"><b>FCS Express Integration</b></p>
<p class="p1">The SA3800 comes with fully integrated FCS Express™ software from De Novo Software, providing advanced analysis tools for detailed data interpretation. This software supports a range of functions, including live gating, spectral overlays, tSNE, Spade, and heat maps. Live gating enables users to quickly and accurately identify positive and negative populations, enhancing the reliability of target population detection.</p>
<p class="p1"><b>System Shutdown and Maintenance</b></p>
<p class="p1">At shutdown, the SA3800 software guides users through pre-cleaning procedures and automatically shuts down the instrument. The system also includes software wizards for bleach cleaning and rinsing, ensuring that the instrument is properly maintained and ready for future use.</p>
<p class="p1">In summary, the Sony SA3800 spectral cell analyzer stands out for its integration of advanced spectral technology, robust automation, and user-friendly software. Its ability to handle complex multicolor workflows with precision and ease makes it an ideal choice for research facilities seeking a high-performance, versatile analyzer. By combining cutting-edge optical technologies with comprehensive automation and intuitive software, the SA3800 offers a powerful solution for cellular acquisition and analysis, facilitating groundbreaking research in cellular biology.</p>
<p class="p4">4o mini</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>CGX10 Cell Isolation System</title>
		<link>https://advena-bio.ae/shop/cell-biology/cell-isolation-systems/cgx10-cell-isolation-system/</link>
		
		<dc:creator><![CDATA[Hattorihanzo]]></dc:creator>
		<pubDate>Thu, 29 Aug 2024 06:40:40 +0000</pubDate>
				<guid isPermaLink="false">https://advena-bio.ae/?post_type=product&#038;p=5767</guid>

					<description><![CDATA[<p class="p1">The CGX10 is designed to fit your GMP environment with its sterile single-use consumables which ensure operation as a fully-closed system</p>]]></description>
										<content:encoded><![CDATA[<p class="p1">The CGX10 Cell Isolation System represents a breakthrough in the field of cell production and sorting, specifically designed to meet the rigorous demands of GMP-compliant environments. As the only fully closed cell isolation system available, the CGX10 sets a new standard for cell sorting applications, combining superior isolation capabilities with user-friendly operation and unmatched flexibility. This system is particularly valuable in the rapidly advancing fields of cell and gene therapies, where precise cell sorting and isolation are critical for the development of effective treatments.</p>
<p class="p1"><b>Innovative Design for GMP Compliance</b></p>
<p class="p1">One of the key advantages of the CGX10 Cell Isolation System is its fully closed design, which is essential for maintaining GMP compliance during cell production processes. Traditional flow cytometers, which have been widely used in research laboratories and early-phase clinical studies, often fall short in GMP environments due to their complex design and the potential for inducing stress or damage to sorted cells. The CGX10 overcomes these limitations by providing a robust, closed system that minimizes the risk of contamination and ensures the highest cell viability during the sorting process. This makes it an ideal choice for environments where strict regulatory standards must be met.</p>
<p class="p1"><b>Superior Cell Isolation with Multi-Marker Selection</b></p>
<p class="p1">The ability to isolate cells based on multiple biomarkers is a crucial feature of the CGX10 system. In cell and gene therapies, it is often necessary to identify and isolate specific immune cells that exhibit the desired phenotype, which may be defined by the presence of one or more biomarkers. Multi-marker-based cell isolation not only enhances the purity of the isolated cells but also allows for the selective elimination of non-target cells, such as over-differentiated T cells, which may be therapeutically ineffective. By ensuring that only the most relevant cells are selected, the CGX10 improves the overall efficacy of cell-based therapies.</p>
<p class="p1">In contrast to traditional flow cytometers, which are typically limited in their ability to handle complex multi-marker sorting in a GMP setting, the CGX10 is designed to excel in these environments. Its advanced technology allows for precise, high-purity isolation of target cells while maintaining their viability, making it a critical tool for researchers and manufacturers involved in the development of advanced therapy medicinal products (ATMPs), including cell and gene therapies.</p>
<p class="p1"><b>Streamlined Operation for Efficient Cell Production</b></p>
<p class="p1">Ease of operation is another hallmark of the CGX10 Cell Isolation System. The system is designed to provide a seamless user experience, making it accessible to trained laboratory technicians who may not have specialized expertise in flow cytometry. This is particularly important in GMP-compliant environments, where the complexity and subjectivity of conventional sorter platforms can be a significant barrier to efficient cell production. The CGX10 simplifies the cell isolation process, reducing the need for extensive operator training and minimizing the potential for user error.</p>
<p class="p1">The system’s intuitive interface and automated processes allow for a smooth transition from process development to full-scale cell production. This flexibility is essential for laboratories and manufacturing facilities that are scaling up their operations to meet the growing demand for cell-based therapies. By streamlining the workflow, the CGX10 enables researchers and manufacturers to focus on the critical aspects of their work, such as optimizing cell culture conditions and ensuring the quality of the final product.</p>
<p class="p1"><b>Application in Advanced Cell and Gene Therapies</b></p>
<p class="p1">The CGX10 Cell Isolation System is specifically designed for use in research, process development, and manufacturing environments related to advanced therapy medicinal products (ATMPs), including cell and gene therapies. These fields have seen significant progress in recent years, driven by the need to develop more effective treatments for a range of diseases. The ability to isolate specific cell populations with high precision is a key factor in the success of these therapies, and the CGX10 provides the tools needed to achieve this.</p>
<p class="p1">It is important to note that the CGX10 and its related products are intended for ex vivo cell separation processing only. They are not designed for therapeutic, diagnostic, or in vivo applications in humans. Any clinical use of the cells processed with the CGX10 must adhere to the relevant regulations, and it is the responsibility of the user to ensure compliance with these standards. The CGX10 system is not sold as a medical device, and its use in clinical applications is subject to the appropriate regulatory approvals.</p>
<p class="p1"><b>Ensuring the Highest Standards of Cell Production</b></p>
<p class="p1">In the context of GMP-compliant cell production, the CGX10 Cell Isolation System offers unparalleled reliability and performance. Its closed design, multi-marker selection capabilities, and user-friendly operation make it an ideal choice for laboratories and manufacturing facilities that require precise, high-purity cell sorting. As the demand for cell and gene therapies continues to grow, the CGX10 provides the flexibility and efficiency needed to support the development of these innovative treatments.</p>
<p class="p1">Moreover, the system’s ability to maintain high cell viability throughout the sorting process is crucial for the success of cell-based therapies. By minimizing the potential for stress or damage to the sorted cells, the CGX10 ensures that the final product is of the highest quality, which is essential for both research and clinical applications. This makes the CGX10 an invaluable tool for advancing the field of regenerative medicine and for bringing new therapies to market.</p>
<p class="p1"><b>Conclusion</b></p>
<p class="p1">The CGX10 Cell Isolation System represents a significant advancement in the field of cell sorting and isolation, particularly in the context of GMP-compliant environments. Its fully closed design, multi-marker selection capabilities, and streamlined operation set it apart from traditional flow cytometers, making it the ideal choice for laboratories and manufacturing facilities involved in the development of advanced cell and gene therapies. As the only fully closed system available for GMP-compliant cell production, the CGX10 offers the reliability, flexibility, and ease of use needed to support the growing demand for high-quality cell-based therapies.</p>
<p class="p1">In summary, the CGX10 Cell Isolation System is not just a tool for cell sorting; it is a comprehensive solution for researchers and manufacturers working at the forefront of regenerative medicine. With its ability to deliver high-purity, viable cells in a GMP-compliant environment, the CGX10 is poised to play a crucial role in the advancement of cell and gene therapies, ultimately improving patient outcomes and driving innovation in the field of medicine.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>FP7000 Spectral Cell Sorter</title>
		<link>https://advena-bio.ae/shop/cell-biology/flow-cytometry-cell-sorting/fp7000-spectral-cell-sorter/</link>
		
		<dc:creator><![CDATA[Hattorihanzo]]></dc:creator>
		<pubDate>Thu, 29 Aug 2024 06:26:04 +0000</pubDate>
				<guid isPermaLink="false">https://advena-bio.ae/?post_type=product&#038;p=5765</guid>

					<description><![CDATA[<p class="p1">The new FP7000 Spectral Cell Sorter is configurable with up to 6 lasers and 182 detectors, and supports high speed, 6-way spectral cell sorting</p>]]></description>
										<content:encoded><![CDATA[<p class="p1">The FP7000 Spectral Cell Sorter is a cutting-edge instrument designed to meet the demands of modern, high-parameter cell sorting applications. Built on Sony&#8217;s patented spectral technology, this system offers a sophisticated combination of optics, electronics, and fluidics, providing researchers with the ability to sort cells across a vast array of parameters, supporting more than 44 distinct colors. The FP7000 integrates seamlessly with workflows from Sony&#8217;s cell sorter portfolio, offering unparalleled automation, precision, and efficiency. It is an ideal solution for busy laboratories that require both simple and complex high-parameter sorting capabilities.</p>
<p class="p1"><b>Unparalleled Spectral Technology for Advanced Sorting</b></p>
<p class="p1">At the heart of the FP7000 is Sony&#8217;s patented spectral technology, which sets it apart from conventional flow cytometry and cell sorting systems. Unlike traditional systems that rely on specific optical filters for each fluorochrome, the FP7000 employs spectral technology that captures the entire emission spectrum of each fluorochrome, enabling the detection of more than 44 colors simultaneously. This capability is further enhanced by the system’s ability to detect autofluorescence signals from 6 lasers—ranging from ultraviolet to near-infrared wavelengths. The FP7000 is equipped with 182 photomultiplier tube (PMT) detectors, ensuring comprehensive data acquisition and enabling researchers to analyze complex cell populations with high precision.</p>
<p class="p1">The system&#8217;s optical capabilities are closely aligned with Sony&#8217;s ID7000™ Spectral Cell Analyzer, allowing for smooth assay transfer between analysis and sorting. This feature is particularly beneficial for researchers who need to replicate their analyses on different instruments, ensuring consistency and reliability in their experiments. The FP7000&#8217;s optical system is also capable of detecting particles as small as 100 nanometers, making it suitable for a wide range of applications, from basic research to clinical diagnostics.</p>
<p class="p1"><b>High-Performance Sorting for Diverse Applications</b></p>
<p class="p1">One of the standout features of the FP7000 is its high-speed, real-time spectral unmixing capability, which allows for the simultaneous detection and sorting of cell populations at rates of up to 25,000 events per second. This high throughput is achieved without compromising accuracy, thanks to the system&#8217;s patented unmixing algorithm. This algorithm is designed to resolve closely spaced fluorochromes with exceptional precision, eliminating the need for traditional compensation techniques, which can be subjective and prone to error. As a result, the FP7000 produces high-quality, reproducible data that is essential for complex multicolor experiments.</p>
<p class="p1">The FP7000 supports a wide range of nozzle sizes, which can be easily interchanged to accommodate different cell types and sorting requirements. This flexibility is crucial for researchers working with diverse samples, as it allows for optimized sorting conditions tailored to the specific needs of each experiment. The system&#8217;s sheath excitation technology ensures robust operation across different nozzle sizes, forming stable droplets at frequencies ranging from 12kHz to 100kHz and at pressures between 70 kPa and 600 kPa. This versatility enables the FP7000 to perform both bulk sorting into tubes and high-precision single-cell sorting into multiwell plates, making it suitable for a variety of downstream applications.</p>
<p class="p1"><b>Automation and Workflow Integration</b></p>
<p class="p1">The FP7000 is designed with automation in mind, making it accessible to researchers of varying expertise levels. One of the key features of the system is the CoreFinder™ algorithm, which automates several critical steps in the sorting process. This includes optical alignment, laser delay optimization, droplet calibration, sort delay optimization, and side stream adjustment. By automating these processes, the FP7000 eliminates the subjectivity associated with manual adjustments, ensuring consistent performance and reducing the likelihood of operator error. This automation not only streamlines the workflow but also significantly reduces the time required for instrument setup, allowing researchers to focus on their experiments rather than on the technical aspects of the sorter.</p>
<p class="p1">In addition to CoreFinder™, the FP7000 features guided workflows that further simplify the operation of the system. These workflows include the Spectral Reference Library, which provides a comprehensive database of spectral signatures for commonly used fluorochromes. This library can be used to streamline the setup of experiments, making it easier for researchers to select the appropriate settings for their specific applications. The system also includes an autofluorescence unmixing feature, which enables the identification and removal of autofluorescence signals from the data. This is particularly important when working with heterogeneous samples that may contain cells or particles with high autofluorescence, as it improves the resolution of dim signals and enhances the overall quality of the data.</p>
<p class="p1"><b>Real-Time Data Analysis and Flexibility</b></p>
<p class="p1">The FP7000 is not only a powerful sorter but also an advanced analytical tool. The system&#8217;s real-time spectral unmixing capability allows for the live analysis of data as it is being acquired, providing researchers with immediate feedback on their experiments. This real-time analysis is complemented by the system&#8217;s ability to perform 6-way sorting, which enables the isolation of multiple cell populations simultaneously. This feature is particularly useful for researchers who need to sort complex samples into multiple subsets for downstream applications, such as single-cell sequencing or functional assays.</p>
<p class="p1">The system&#8217;s flexibility extends to its data output formats, which are compatible with a wide range of third-party analysis software. This ensures that researchers can easily integrate the FP7000 into their existing workflows without the need for extensive reformatting or data conversion. The FP7000&#8217;s user-friendly interface and intuitive software design make it easy to learn and use, even for those with limited experience in spectral cell sorting. The software includes customizable wizards and guided protocols that assist users in setting up experiments, performing routine maintenance, and troubleshooting common issues.</p>
<p class="p1"><b>Meeting the Needs of Modern Laboratories</b></p>
<p class="p1">The FP7000 Spectral Cell Sorter is designed to meet the diverse needs of modern laboratories, from basic research to complex, high-parameter applications. Its combination of advanced spectral technology, high-performance sorting, and automated workflows makes it an indispensable tool for researchers seeking to push the boundaries of cell sorting and analysis. Whether you are working with simple two-color assays or complex panels with more than 44 colors, the FP7000 provides the reliability, precision, and flexibility needed to achieve your research goals.</p>
<p class="p1">In conclusion, the FP7000 Spectral Cell Sorter represents a significant advancement in the field of flow cytometry and cell sorting. With its unparalleled spectral technology, robust performance, and user-friendly design, the FP7000 is well-equipped to handle the most demanding sorting applications, making it a valuable asset for any laboratory. Whether you are conducting basic research or pursuing cutting-edge applications, the FP7000 provides the tools and capabilities needed to deliver high-quality, reproducible results with confidence.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Mabtech IRIS™ 2</title>
		<link>https://advena-bio.ae/shop/cell-biology/elispot-fluorospot-analysis/mabtech-iris-2/</link>
		
		<dc:creator><![CDATA[Hattorihanzo]]></dc:creator>
		<pubDate>Wed, 28 Aug 2024 11:10:59 +0000</pubDate>
				<guid isPermaLink="false">https://advena-bio.ae/?post_type=product&#038;p=5700</guid>

					<description><![CDATA[<p class="p1">ELISPOT and FLUOROSPOT analyzes up to four analytes with unmatched accuracy and speed.</p>]]></description>
										<content:encoded><![CDATA[<p class="p1">The IRIS 2 is a versatile FluoroSpot and ELISpot reader designed to meet the demands of modern laboratories. Capable of analyzing up to four analytes simultaneously, it offers unparalleled accuracy and speed, making it an essential tool for researchers. With the introduction of the new FociSpot application, the IRIS 2 extends its capabilities to quantify virus foci in focus forming assays (FFA). This system is built around Mabtech’s patented RAWspot™ algorithm, ensuring precise spot center detection and accurate counting. Paired with the intuitive Mabtech Apex™ software, the IRIS 2 delivers a plug-and-play experience that simplifies your workflow—just load the plate, select the assay, and press &#8220;read.&#8221;</p>
<p class="p1">The IRIS 2’s flexibility is evident in its ability to handle ELISpot, FluoroSpot (up to four colors), and FociSpot assays. Its precise spot counting capabilities are enhanced by the fixed focus and self-calibrating XY table, which streamline the workflow and minimize user intervention. The intuitive software provides a smooth user experience, with customizable presets for recurring experiments, ensuring that the system is ready for automated plate loading and high-throughput applications.</p>
<p class="p1">Designed for a streamlined workflow, the IRIS 2 is pre-calibrated for ease of use. Users simply need to insert the plate, select the assay type, and press &#8220;read.&#8221; The system records the entire signal from every spot, allowing for post-reading adjustments without the need to re-read the plate. Mabtech Apex™ software further enhances efficiency with its intuitive layout features and automatic data export, speeding up the transition from data acquisition to analysis.</p>
<p class="p1">At the heart of the IRIS 2’s precision is the RAWspot™ algorithm, optimized for detecting the exact location of the spot center. This accuracy is crucial for identifying cells that secrete multiple analytes in FluoroSpot assays. The IRIS 2 also introduces a new dimension of spot data—relative spot volume (RSV)—by extracting a 3-dimensional volume for each spot, corresponding to the amount of secreted analyte. This detailed analysis capability is essential for researchers seeking deeper insights into their data.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Mabtech ASTOR™ 2</title>
		<link>https://advena-bio.ae/shop/cell-biology/elispot-fluorospot-analysis/mabtech-astor-2/</link>
		
		<dc:creator><![CDATA[Hattorihanzo]]></dc:creator>
		<pubDate>Wed, 28 Aug 2024 08:13:30 +0000</pubDate>
				<guid isPermaLink="false">https://advena-bio.ae/?post_type=product&#038;p=5685</guid>

					<description><![CDATA[<p class="p1">Easy-to-use, durable ELISpot reader with fixed focus and self-calibrating features</p>]]></description>
										<content:encoded><![CDATA[<p class="p1"><b>Streamlined Workflow</b></p>
<p class="p2">One of the often overlooked yet time-consuming aspects of ELISpot assays is the data analysis process. The Mabtech ASTOR 2 addresses this issue by offering pre-calibrated settings and efficient analysis tools, significantly reducing the time from data acquisition to a completed analysis. The streamlined workflow allows users to focus on their research without being bogged down by lengthy and complex data processing steps. By minimizing the time required for analysis, Mabtech ASTOR 2 enhances productivity and ensures that results are delivered quickly and accurately, making it an invaluable tool in any laboratory setting.</p>
<p class="p1"><b>Precise Spot Counting</b></p>
<p class="p2">At the heart of Mabtech ASTOR 2’s functionality is its advanced software, powered by the patented RAWspot™ technology. This technology is designed to accurately pinpoint the center of each spot, ensuring precise spot counting. The accuracy of this technology can be observed in its linear counting capability, especially when correlated with cell dilution. Mabtech ASTOR 2 provides linear spot counting even with more than 3,000 spots per well, ensuring reliable data processing across a wide range of experimental setups, including positive controls. This level of precision is crucial for researchers who require consistent and dependable results in their ELISpot assays.</p>
<p class="p1"><b>Read Now, Analyze Later</b></p>
<p class="p2">Mabtech ASTOR 2 offers flexibility in data management by allowing users to select default settings for quick data acquisition. This feature enables researchers to capture data efficiently and then apply preferred spot size, plate layout, and image settings afterward without altering the original data. This capability is particularly beneficial for laboratories that need to meet stringent regulatory requirements, such as those outlined in CFR21 part 11, which pertains to FDA guidelines on electronic records in clinical investigations. With Mabtech ASTOR 2, researchers can rest assured that their data is not only accurate but also compliant with industry standards.</p>
<p class="p1"><b>Ready for Automation</b></p>
<p class="p2">The design of Mabtech ASTOR 2 takes into account the growing need for automation in laboratories, especially for larger projects. In addition to its self-calibration features and responsive software, the ASTOR 2 supports robotic plate loading, making it an ideal candidate for integration into automated workflows. Whether used with a robotic arm or as part of a larger automated system, the ASTOR 2 is versatile enough to fit seamlessly into various setups. Mabtech offers support throughout the automation process, ensuring that each solution is tailored to meet the specific needs of the laboratory.</p>
<p class="p1"><b>Performance Qualification</b></p>
<p class="p2">Reliability and accuracy are paramount when it comes to laboratory equipment, and Mabtech ASTOR 2 is no exception. To ensure that the reader maintains its performance over time, especially under regulatory scrutiny, Mabtech offers a Performance Qualification (PQ) plate. This plate allows users to conduct both quantitative and qualitative tests, verifying that the instrument continues to meet quality specifications. By regularly using PQ plates, laboratories can confidently validate the performance of their ASTOR 2 readers, ensuring that their experiments yield consistent and reliable results. This level of quality control provides peace of mind, knowing that the data produced is both accurate and reproducible.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>LUNA-STEM™ Automated Fluorescence Cell Counter for Stem Cells &#038; SVF</title>
		<link>https://advena-bio.ae/shop/cell-biology/cell-counting/luna-stem-automated-fluorescence-cell-counter-for-stem-cells-svf/</link>
		
		<dc:creator><![CDATA[Hattorihanzo]]></dc:creator>
		<pubDate>Wed, 24 Jul 2024 13:00:11 +0000</pubDate>
				<guid isPermaLink="false">https://u2692146.isp.regruhosting.ru/?post_type=product&#038;p=4667</guid>

					<description><![CDATA[<p class="p1">LUNA-STEM™ precisely counts live, dead, and non-nucleated cells for downstream procedures.</p>]]></description>
										<content:encoded><![CDATA[<p class="p1">Accurate cell concentration and viability are essential for high-quality downstream procedures, especially with tissue-derived cells like stem cells or those from the adipose stromal vascular fraction (SVF). Contamination with red blood cells and debris can complicate counting. The LUNA-STEM™ overcomes these challenges with dual fluorescence and brightfield optics, effectively differentiating live and dead nucleated cells from non-nucleated cells. Staining with nucleic acid dyes allows precise measurement of cell concentration and viability. Within 30 seconds, it provides total and nucleated cell concentrations, viability, and average cell size. High-resolution images visually confirm data, with detailed PDF reports available for transfer or printing.</p>
]]></content:encoded>
					
		
		